Model and SHP EX
PT6A-140
867 SHP
Model and SHP Legacy
PT6A-114A
675 SHP
Engine Description
PT6 Reverse Free Flow Turbine. Compressor Turbine and Power Turbine are not connected
Air enters in to the engine through the intake on the left side of the engine cowling. It then goes past the inertial seperator (Bypass position ; air turns 90 degrees and heavier objects proceed out the bypass door) into the 3 stage axial compressor (Compresses air horizontally “axial” effiecient at lower RPM) through the single stage centtrifugal compressor (7:1 compression ratio) into the annualar can which reverses the direction of airflow. 2 igniters light the mixture and sends it through the gas generator (101.6% is 38,100 and 100% 37,500) some of the combustion exits throught the exhaust and the rest through the power turbine (33,000RPM) to the gear reduction box which uses a sun gear to reduce the speed to 1900RPM
Engine Compression Ratio
7:1
Number of Axial Stages
3
Number of Centrifugal Stages
1
Power Turbine RPM
33,000
Gas Generator RPM
37,500