Ignition limitations:
- sub 1249 (no ASC 304)
30 sec on and 30 sec off ….or
5 min. on then 30 min. off - 1250 + (or w/) ASC 304
NO limitation
Max start TGT?
Ground - 700°C momentarily
Air - 780°C momentarily (200 - 324 kts < 25,000)
Max over temp / over speed:
LP - 98.3
HP - 102.6
TGT - 801-820°C (for max 20 sec.)
Max T/O or GA engine limits:
LP - 95.5
HP - 99.7
TGT - 716-800°C for 5 min. (10 min OEI)
Max continuous engine LP, HP and TGT?
LP - 95.5
HP - 97.5
TGT - 715°C no time restriction
Min idle
ground - HP 46.6
approach - HP 67.0
Max Reverse:
HP - 88.0
TGT - 695°C
* initiate cancellation by 70 kts
** s/n 1000-1143 or no ASC 166? limited to 1 min. per 30 min.
Static operating limitation of LP fan in wind?
60-80% LP with crosswind greater than 15 kts is not permitted.
Can you use TRs to reverse?
No.
Min. oil temps?
to start - 40°C
to advance power levers - 30°C
Max oil temp.?
105°C
(120°C for 15 min.)
Min oil pressure at idle and T/O?
Idle - 16 PSI
T/O - 30 PSI
Min oil pressure in flight?
97.5% HP - 25 PSI
92% HP - 22 PSI
84% HP - 19 PSI
76% HP - 16 PSI
The engine starter duty cycle:
3 - 30 second start cycles with a 3 min. delay between cycles and 15 min. delay after 3rd start attempt
Takeoff EPR limit?
Not to exceed rated value 0.01