power supplies Flashcards
Commercial power that feeds our power supplies and home are _______ or ________ VAC
120 or 240
Commercial power that feeds our power supplies is ______Hz
60
Commercial power that feeds our power supplies is a _________ wave
Sine
3 battery power supplies have a voltage of ______
36V
What changes the DC battery volts to VAC?
Power Supply Inverter
What changes the input VAC from 120V or 240V to 60V or 90V output?
Step Down Transformer
What device combines the PS voltage with the network RF signal?
LPI (Line Power Inserter)
SPI
Service Power Inserter
What devices are used to direct AC power?
Fuses or Shunts
This device has a low pass filter on each leg, this prevents RF leakage in the Power Supply
LPI (Line Power Inserter)
Powering architecture where there is only one power supply used to power the entire node and actives
Centralized powering
this power architecture is the most commonly used
distributed powering
Center Conductor Resistance + Sheath Resistance
DC Loop Resistance
Span current X Span resistance
Voltage drop
Voltage difference between batteries should be no more than:
0.3VDC
Battery terminals should be protected w/ corrosion inhibitor like NO-OX or NCP-2, True or False
True
Before disconnecting the batteries always turn off the _______ ________ first
Battery Breaker
Use a ________ to accurately measure power supply output VAC
True RMS Volt Meter
The most accurate & Reliable way to test batteries is to test them under _______ Conditions
Load
When testing with a load tester, batteries should or should not be disconnected
Should