Power Generation Flashcards
Two types of interfaces?
Power ( Voltage) and Signal ( Comms)
What is the purpose of PWRSS?
Fire Control Equipment receiving primary power.
Buffers, converts, regulates, distributes, monitors and controls supplied power
SWS[Loads] launcher, DRS, MTRE, VAMP, Swsmin, missile
Purpose of tie breakers?
Connects 1-2:source together. If one removed there is still a supply to FC systems
What Equipment makes up the PCME
PDE PBE PCE PMCE
What Equipment is in the PCME?
6xPMA 3xVSA 2xAMA 1xDC voltmeter
How many buffers to launch missile
Any 2 of 3
Alarm indication on 5v?
Indicating push button, to observe supply and reset.
Indication of PWRSS on each door
Visual indicator of abnormal status, provided by
PDE PBE PCE PCME
270v DC ground fault
Resistance between leg of distribution and ground Less than 75K ohms
28v DC ground fault
Distribution and ground Less than 7K - 62K ohms
Online monitoring, threshold impedance
Impedance path of less than 9K ohms to ground
Purpose of the PPS?
Provide 115v 1ph 5.1Khz power to the Command sequencer and permit setting of RBA fuses
Two methods of detecting ground faults
Online fault monitoring- continuous
Ground fault test SMP- periodic
PCM
Software program that executes in the DCSS
Displays at Fire Control console
Name two missile test modes?
Fuse test and Tactical mode