Positive Pressure Ventilation M.P.202.12D Flashcards

1
Q

Positive pressure ventilation (PPV) has many benefits to fire operations
PPV can reduce what?
PPV can improve what?
PPV removes what?

A
  • Reduces the fires ability to propagate and advance
  • Reduces firefighter heat stress
  • Reduces damage to structure
  • Reduce the risk and need of roof ventilation
  • Improving atmosphere–thus improving patient survivability profiles
  • Visibility increases

-Removes heat and smoke improving ability to conduct S/R

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

All offensive fire operations qualify for early application of PPV

True or false

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Fans should be placed at point of entry from unburned side of fire how many feet back from the door?
Objective is to create a pressure “cone” effect around the door.

A

12’-15’ back

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When additional fans are needed, placing two or more in “________” is more effective than side-by-side.

A

“tandem”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

PPV must have 2 major items?

A
  1. An “exit” for the pressurized air and must be located in the fire area.
  2. PPV must be injected from the unburned side of fire.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Too many openings or exit points
reduce the effectiveness of PPV. In some cases, windows and doors that are already open may need
to be What?

A

closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

ATTIC FIRES-
Isolated attic fires can benefit from PPV
True or false

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

ATTIC FIRES-
During initial attack, fire crews should use small openings in the ceiling for _____ application. This will prevent the clear environment below the ceiling from rapidly filling with _______.

A
  • water

- smoke

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Multi-story/High-rise PPV

-________ should be used

A

-Stairwell

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Multi-story/High-rise PPV

-An ____ in the fire area (window) is first choice

A

-exit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Multiple fans may be required. A fan will be needed at the entry to the fire floor.
How many fans may be needed at the base of the building?
What locations may additional fans be needed?

A
  • two or more

- On landings at various levels in the stairwell

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Regarding PPV for Exposure Control, it is most effective with what and give two examples.

A

Most effective with common attics (strip shopping centers, apartment complexes)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

For exposure control, where would the fans be placed?

A

At an entry point at most severe exposure first

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

After fans have been placed at an entry point at the most severe exposure, what receives PPV next?

A

The second most critical exposure would then receive PPV

How well did you know this?
1
Not at all
2
3
4
5
Perfectly