Plumbing 5th Importance Flashcards
An engineered vent system must be approved in accordance with Section 301.5 and designed by:
A registered design professional
The design and sizing of a vent system shall be permitted to be determined by accepted engineering practices. The system shall be designed by a registered design professional and approved in accordance with Section 301.5.
(2018 UPC - 301.5 Alternative Engineered Design.)
The addition to, alteration, erection, installation, maintenance relocation, repair, replacement, or use of plumbing systems within this jurisdiction must comply with the provisions of the:
Uniform plumbing code
The provisions of this code shall apply to the erection, installation, alteration, repair, relocation, replacement, addition to, use, or maintenance of plumbing systems within this jurisdiction.
A room equipped with a shower or bathtub is a___________.
Bathroom
A room equipped with a shower, bathtub, or combination bath/shower.
Gasketing on gasketed doors or frames must be furnished according to the published listings of the:
Door, frame, or gasketing material manufacturer
Gasketing on gasketed doors or frames shall be furnished in accordance with the published listings of the door, frame, or gasketing material manufacturer.
True or False: Alternate water source systems shall be designed in accordance with this chapter by a person registered or licensed to perform plumbing design work.
True
Alternate water source systems shall be designed in accordance with this chapter shall be designed by registered design professional or licensed person who demonstrates competency to design the alternate water source system as required by the Authority Having Jurisdiction. Components, piping and fittings used in an alternate water source system shall be listed.
The UPC is an ordinance providing__________
requirements and standards for the protection of the public health, safety, and welfare.
Minimum
This code is an ordinance providing minimum requirements and standards for the protection of the public health, safety, and welfare.
fron, steel, copper and copper alloy pipe must be standard-weight:
Ips
Iron, steel, copper, and copper alloy pipe shall be standard-weight iron pipe size (IPS) pipe.
For the construction of drainage and plumbing systems, all devices, fixtures, or materials used or entering must:
Comply with approved applicable standards
Pipe, pipe fittings, traps, fixtures, material, and devices used in a plumbing system shall be listed (third-party certified) by a listing agency (accredited conformity assessment body) as complying with the approved applicable recognized standards referenced in this code and shall be free from defects. Unless otherwise provided for in this code, materials, fixtures, or devices used or entering into the construction of plumbing systems, or parts thereof shall be submitted to the Authority Having Jurisdiction for approval.
All pipe, pipe fittings, traps, fixtures, material, and devices used in a plumbing system shall be
______________as required by applicable
referenced standards and a listing agency.
Indelibly marked
Each length of pipe and each pipe fitting, trap, fixture, material, and device used in a plumbing system shall have cast, stamped, or indelibly marked on it any markings required by the applicable referenced standards and listing agency, and the manufacturer’s mark or name, which shall readily identify the manufacturer to the end use of the product. Where required by the approved standard that applies, the product shall be marked with the weight and the quality of the product.
Materials and devices used or entering into the construction of plumbing and drainage systems, or parts thereof shall be marked and identified in a manner satisfactory to the Authority Having Jurisdiction. Such markings shall be done by the manufacturer. Field markings shall not be acceptable.
What is the first step in obtaining a plumbing permit?
Filing an application
To obtain a permit, the applicant shall first file an application therefore in writing on a form furnished by the Authority Having Jurisdiction for that purpose.
An applicant wishing to obtain a permit must file
______________on a form furnished by the Authority Having Jurisdiction for this purpose in writing.
An application
To obtain a permit, the applicant shall first file an application therefore in writing on a form furnished by the Authority Having Jurisdiction for that purpose.
Faucets and diverters shall be connected to the water distribution system so that hot water corresponds to the___________side of the fittings.
Left
Where two separate handles control the hot and cold water, the left-hand control of the faucet where facing the fixture fitting outlet shall control the hot water. Faucets and diverter shall be connected to the water distribution system so that hot water corresponds to the left side of the fittings. Single-handle mixing valves installed in showers and tub-shower combinations shall have the flow of hot water correspond to the markings on the fixture fitting.
No dry or chemical closet (toilet) shall be installed in any building used for human habitation, unless first approved by the___________.
Health Officer
Fixed wooden, or tile wash trays or sinks for domestic use shall not be installed in a building designed or used for human habitation. No sheet metal-lined wooden bathtub shall be installed or reconnected. No dry or chemical closet (toilet) shall be installed in a building used for human habitation, unless first approved by the Health Officer.
How do you know what the local BTU per cubic foot is, in any area?
Ask the gas supplier
Where the gas appliances to be installed have not been specified, Table 1208.4.1 shall be permitted to be used as a reference to estimate requirements of typical appliances. To obtain the cubic feet per hour (m3/h) of gas required, divide the input of the appliances by the average Btu (kW-h) heating value per cubic foot(m3) of the gas. The average Btu (kW-h) per cubic foot (m3) of the gas in the area of the installation shall be permitted to be obtained from the serving gas supplier.
The submission of drawings, plans, specifications, and other such information prior to work regulated by this code commencing may be required by the:
Authority Having Jurisdiction
The Authority Having Jurisdiction shall be permitted to require the submission of plans, specifications, drawings, and such other information in accordance with the Authority Having Jurisdiction, prior to the commencement of, and at a time during the progress of, work regulated by this code. The issuance of a permit upon construction documents shall not prevent the Authority Having Jurisdiction from thereafter requiring the correction of errors in said construction documents or from preventing construction operations being carried on thereunder where in violation of this code or of other pertinent ordinance or from revoking a certificate of approval where issued in error.