PHEP 31 Flashcards

1
Q

TRANSMISSION LINES ARE USED FOR THE PURPOSE OF

A

ALL THREE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

IN DISCUSSING RELATED CHARACTERISTICS OF TRANSMISSION LINES IT CAN BE SAID THAT THE HIGHER THE VOLTAGE

A

THE LOWER THE (I SQUARED R) LOSSES

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

ELECTROSTATIC AND ELECTROMAGNETIC UNBALANCE BETWEEN PHASES IN A 3 PHASE TRANSMISSION LINE IS REDUCED BY

A

TRANSPOSING OR ROTATING THE CONDUCTORS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

THE ENERGY STORED IN THE MAGNETIC FIELDS OF THE CONDUCTOR IS

A

CALLED WATTLESS ENERGY

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

THE STEEL CORE OF ACSR CONDUCTORS DOES NOT

A

CARRY ANY APPRECIABLE AMOUNT OF LOAD CURRENT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

SUSPENSION TYPE INSULATORS

A

ALL THREE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

TRANSMISSION LINE LOSSES DUE TO CORONA MAY BE REDUCED BY ALL OF THE BELOW EXCEPT

A

INCREASING VOLTAGE VALUE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

BUNDLED CONDUCTORS

A

REDUCE INDUCTIVE REACTANCE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

AN ELECTRICAL TRANSMISSION SYSTEM MAY BE CAUSED TO DROP OUT OF STEP OR BECOME UNSTABLE BY

A

ALL THREE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

SWITCHING PERFORMED UNDER SHORT CIRCUIT CONDITIONS IS APT TO BE MOST DISTURBING TO TRANSMISSION LINE WHEN

A

DONE ON THE LOW VOLTAGE SIDE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

THE VOLTAGES INDUCED IN THE LEAD SHEATH OF UNDERGROUND CABLES MAY BE ELIMINATED BY

A

ALL THREE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

A MATERIAL SUCH AS THYRITE WOULD MOST LIKELY BE USED IN

A

A VLV TYPE LIGHTNING ARRESTOR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

ALL OF THE BELOW ARE CONSIDERED AS ADVANTAGES IN THE TRANSMISSION OF HVDC AS COMPARED TO AC EXCEPT FOR

A

THE OVERALL INSULATION REQUIREMENTS MAY BE BASED ON THE PEAK RATHER THAN THE ACTUAL VOLTAGES

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

HVDC TRANSMISSION LINES

A

CANNOT BE PROTECTED FROM FAULTS BY USING CONVENTIONAL CIRCUIT BREAKERS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

IN A HVDC TRANSMISSION SYSTEM

A

THE QUANTITY AND DIRECTION OF POWER FLOW MAY BE CONTROLLED WITH ACCURACY AND EXTREME RAPIDITY

How well did you know this?
1
Not at all
2
3
4
5
Perfectly