PCB's (AUC 266) Flashcards

1
Q

PCB’s…

A

Cooling liquids in electrical transformers and capacitors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the primary consideration at PCB incidents?

A

SAFETY of civilians and fire personnel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A PCB transformer will be marked (required by EPA), at what level?

A

500 or MORE ppm of PCB

NYC- 0-49 NON PCB
50-499 PCB contaminated

-both are marked only NYC regulations by DEP

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Are VEHICLES carrying PCB TRANSFORMERS marked .?

A

YES

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

An unmarked transformer is…?

A

assumed to contain PCBs until a LABORATORY TEST rules out PCB contamination

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When are vehicles carrying PCB CONTAINERS..marked?

A

500 or more ppm

PCB contaminated liquid (50-499 ppm)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

All PCB TRANSFORMERS are registered with the FDNY?

A

YES

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Where does a unit direct people looking to register PCB Transformer?

A

Toxic Substance Unit, Bureau of Fire Prevention

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What info do these registrations provide?

A

address/location
physical location in the building
dielectric fluid (PCB/mineral..etc)
name and phone number of contact

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Combustible materials may not be stored within a PCB TRANSFORMER enclosure, within?

A

5 METERS of pCB transformer enclosure or unenclosed transformer (16.4 feet)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

How long can PCB items and PCB liquids be stored?

A

PERIOD OF 1 YEAR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Temporary storage of PCBS/ PCB liquid?

A

PCB items (500 or greater) and liquid (50-499) not exceeding 30 days

LIQUIDS 500 OR GREATER CANNOT BE STORED IN A TEMPORARY SITE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

EPA marking format…?

A

letter and stripping on a WHITE or YELLOW background

6”x6” square or 2”x2” square

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Oil is a mineral oil, originally PCB free, HOWEVER, it may have…?

A

become PCB contaminated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

A transformer cooled by AIR..will…

A

NOT CONTAIN PCB

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

THE NYC fire Dept. considers with any amount of PCBs….

A

A PCB TRANSFORMER

17
Q

Entrance into the contaminated or suspected are shall be…?

A

Kept to A MINIMUM

-First arriving Officer shall seek out person in charge of the premises in order to determine location and extent of fire or emergency, and the amount of hazardous material involved….this person may NOT BE AWARE OF PRESENCE OF PCB’S

18
Q

Deactivation of transformers or capacitors shall be performed by?

A

Con ED or Engineering Personnel

-no member of the FD should attempt this deactivation upon instruction of engineering personnel

19
Q

Proper extinguishing methods?

A

Structural-water

liquids-foam or FOG

20
Q

USE SCBA’s even in..?

A

LIGHT SMOKE CONDITION

21
Q

Breathing apparatus shall be used at all times, unless..?

A

the IC confirms that are is free of TOXIC GASES

-NO SMOKING, EATING OR DRINKING

22
Q

Members exposed should..?

A
  • be confined to designated area until decon
  • decon along with equipment
  • examined by medical officer
23
Q

Prime consideration is given to?

A

EVACUATION of Fire floor and all areas exposed (even if light haze exists)

24
Q

Decon procedures in the ERP are implemented when?

A

members or equipment are exposed to levels of PCB’s of 50 PPM or higher

25
Q

Ohsa unit…?

A

Car 68

will respond to PCB emergencies, as needed

26
Q

SIGN (page 9)

A

“Caution”

“Askarel Filled equipment”

  • high concentration of PCB’S
  • THIS SIGN will be found on TRANSFORMER VAULT DOOR
  • arcing or occurring or has occurred, present hazardous condition
  • SCBA must be worn
27
Q

M2 Cars?

A

A-pantograph–even numbered
B- NO pantograph-odd numbered

M2- orange stripe on each side and pantograph on roof of car A

pantograph receives power from from catenary wires

Amtrak/NJ transit- PCB decals

28
Q

NYC Dept. of Environmental Protection (DEP) has authorized marking format for ?

A

CITY OWNED TRANSFORMERS ONLY

29
Q

PCB CONTAMINATED (50-499) and NON PCB TRANSFORMER (0-49) decals will ONLY be place on NYC owned transformers …all other will be EPA regulations

A

unless “0” is shown—–

FD will consider a transformer in ANY AMOUNT OF PCBS a PCB transformer