Part III Flashcards
3 Parts of MRI Suites
Gantry
Control Console
Computer Network/System
Operating console is composed of :
-imaging acquisition
-image processing
Operating console [added]
Start-up
Image acquisition
Prescan Calibrators
Image Scanning
Image Processing/Display/Manipulation
MRI computers is composed of:
Multitasking operating system
Control Computer
Acquisition Control System
Image Reconstruction
Processing Computer
MRI system electronics
Frequency Synthesizer
RF Amplifier
Gradient Coil Power Supply
Sequencing System
Digital Signal Acquisition System
Digital Image Processing System
Ancillary Equipment
Power Injectors
Infusion Pumps
Pads and Pillows
Cryogenic Filling Equipment
CM used in MRI
Gd DPTA -contrast (paramagnetic)
Diethylenetriamine Penta-acetic acid
[ancillary equip.] Facilitate introduction of CM, Nonmagnetic
Power injectors
[ancillary equip.] Used for introduction of saline/fluid, automatic set rate/amount
Infusion Pumps
[ancillary equip.] used for pt comfort, headphones, pillows, blankets
Pads and pillows
[ancillary equip.] cooling system used to ensure magnetic property
Cryogenic filling equipment
[operating console-start- up] energizes the system
Power On/Off
[operating console-start- up] should be used if the pt is in danger (in case of adverse fx, claustrophobic)
Emergency Off
[operating console-start- up] installed with TV system for communication
Intercom - speaker and Tv monitor to ensure pt is not moving
[operating console-start- up] selection of pulse sequence, pulse delay timings, other parameters
Scan Control Module
[operating console-start- up] SLICES (no of gaps); scout images
Image-Guided Graphical Prescription
[operating console-start- up] review the image (display windowing), parametric imaging processing
Image Display System
[operating console] involves stimulation of H and receiving of signal
Image Acquisition
[operating console-image acquisition] often automatic, accommodate the body part/FOV
Tuning Control
[operating console-image acquisition] RT can modify, 90-90deg..90-180deg/..
Pulse Sequence Selection
[operating console-image acquisition] selection of repetion time [TR] and echo time [TE]
Timing selection
[operating console-image acquisition] optimize image contrast and SNR (reduce artifacts)
X and y axis to get FID
RF pulse flip angle selection
[operating console-image acquisition] Matrix Size
256x256; larger matrix size = better image, longer imaging time
[operating console-image acquisition] FOV
reduced FOV = better spatial resolution (requires more signal acquisition)
[operating console-image acquisition] amount of FID needed
Number of Signal Acquisitions (NSA)
Number of Excitations (NEX)
Number of Averages (NA)
[operating console-image acquisition] Slice Thickness
Reduced slice thickness improves spatial resolution
Thicker slice = < detail
[operating console-image acquisition] affects the SNR and chemical shift artifact
Range of frequency/signals
Receiver Bandwidth (BW)
[operating console-image acquisition] pre saturation pulses to eliminate signals from certain samples (fats and water)
Magnetization Preparation Schemes
[operating console-image acquisition] 2D and 3D images, usually for advanced imaging system - possible in MRI arteriogram
Reconstruction Strategies
[operating console-image acquisition] number. Of slices, gaps b/w slices, orientations - sagittal , coronal, axial
Slice Positioning and Orientation
[operating console] role of computer system
Prescan Calibrators
[operating console-prescan calibrators] accommodate the patient’s size - adjust RF coil to match patient habitus
Transmit/Receive Coil Tuning
[operating console-prescan calibrators] establishes the slice position and resonance frequency of fats and water photons (automatic)
Center Frequency Tuning
[operating console-prescan calibrators] sets the duration that radio frequency is on and the amount of power to generate the radio frequency (if short-blurry)
Pulse Amplitude Calibration
[operating console-prescan calibrators] ensures that signal is not too low (noisy image) or too high (image distortion)
Receiver Gain Control
[operating console-prescan calibrators] makes the MF homogenous
Autoshimming
Importance of Magnetic Shimming
-maintain homogenousfield
-minimize fringe field-stray field that can interfere with electronic devices
Magnet ensure safety within [..]
5G
Protect the magnet from outside things that can affect the homogenous MF
Shimming
Protect public and environment
Fringe field
Two types of magnetic shielding
Passive - walls of MRI gantry (s), MRI suite (f)
Active - magnet in gantry
[operating console-Imaging Scanning] Patient Positioning
Uses: surface coils/phased array coils
Laser positioning system
Surface coil purpose:
Added on POI, receive only
Shorten distance -enhance contrast
[operating console-Imaging Scanning] Patient Monitoring
Uses TV and intercom
[operating console-Imaging Scanning]inspect date for quality and positioning of data
Image Quality Inspection
[operating console] Imaging Scanning
Pt Positioning
Pt Monitoring
Image Quality Inspection
[operating console-Image Processing/Display/Manipulation] set the contrast and shades of gray. Wider range in MRI
Window Width Level
[operating console-Imaging processing/ display/ manipulation] pointer
Cursor On/Off
[operating console-Imaging Processing] calculation of area of measure and average and standard deviation of pixel values
Region of Interest (ROI)
[operating console-Imaging processing] magnify the image. Some may produce fixed magnification. Reconstructive [..] is not possible in MRI
Zoom
[operating console-Image Processing] selects pixel values within a given range for special attention
Highlight
[operating console-Imaging Scanning] simultaneous display of multiple images or portions of an image on one wide screen
Display Matrix Format
[operating console-image processing/display manipulation] plotting of pixel values along the identified axis in a line graph
Profile/ Histogram
[operating console-image processing/display manipulation] selects pixel values within a given range for special attention
Highlight
[operating console-image processing/display manipulation] simultaneous display of multiple images or portions of an image on one wide screen
Display Matrix Format
types of computer system
-control computer
-acquisition control computers
-image processing computer
control computer provides an interface with the operator for:
control and display functions
data archiving
and network communications
[computer system] computer that control the gantry, receive instructions from control computers
-converts instructions to specific pulses, timing delays and amplifier gain
acquisition control computers
location of acquisition control computer
equipment room
[computer system] for image reconstruction
image processing computer
[computer system] should have high capacity to store data for manipulation; fast to handle the high rate of data acquisition; can accommodate enormous no. of calculations
image processing computer
image processing time: [..]
1 sec - to entertain more frames
additional subsystems to assist in the functioning of computers
MRI System Electronics
[MRI System Electronics] produce RF pulse, generates the fundamental resonance frequency used to excite the magnetic nuclear spins
Frequency Synthesizer
[MRI System Electronics] produces low-level sinusoidal wave signal from a fixed time base oscillator
[high intensity = low RF frequencu
Frequency Synthesizer
types of RF Synthesizer
direct digital synthesizer (DDS)
dividing time
[RF Synthesizer] creates arbitrary waveforms using frequency and pulse-tunable output signals
direct digital synthesizer (DDS)
[RF Synthesizer] fixed frequency precision clock source referenced to DDS
MRI System Clock
[MRI System Electronics] the DDS scales the frequency clock using a programmable binary tuning word that is typically […] long
Dividing Time
24-48 bits
[MRI System Electronics] increase signal out put from the frequency synthesizer; should be immune to load changes
Radiofrequency Amplifier
RF energy is [..] to RF frequncy
directly proportional
T/F MRI amplifiers must have an increasing power ratings when used with higher field magnets
T
RF AMPLIFIER : 1.5 T maximum outputs
18 kW -25 kW
RF AMPLIFIER : 3 T maximum outputs
30 kW - 40 kW
[MRI System Electronics] operates in a current-driven mode; installed with cooling system to ensure stability of temperature
Gradient Coil Power Supply
Gradient Coil Power Supply : peak output current can range up to [..] and peak voltages up to [..]
1 kA
500 V
high powered GPS for the whole body categories
-Linear GPS
- Switching GPS System and Resonant System
-Pre-emphasis circuitry module
[GPS] deliver power directly to the coils
linear GPS
[GPS] uses energy storage strategies to reduce power dissipation [backup power]
Switching GPS System and Resonant System
[GPS] modifies the gradient pulse waveform to minimize EDDY CURRENT
Pre-emphasis circuitry module
result of current opposing the cause that produced them, produced in any conducting material subjected to changing MFs
EDDY CURRENT
[MRI System Electronics] inorder to accept current, magnetic coils must have resistance
Magnetic Power Supply
[MPS]
persistent switch
magnetic power supply
stabilized Bo Field
[MPS} superconducting heat switch may be used - help in giving current
Persistent Switch
programmed to slowly inject current until the specific MF had been attained
Magnet power supply
[MPS] the current to the switch is turned off
Stabilized Bo field
[MRI System Electronics] traffic cop of MRI Scanner that takes instruction from the computer and setting up proper parameters; controls the RF transmitter and gradient amplifiers to cause an MR image
Sequence System (Pulse Programmer)
[MRI System Electronics] sets parameters such as bandwidth for the subsystem receiver
Sequence System (Pulse Programmer)
[MRI System Electronics] signals (from H atoms) -receiver - preamplifiers
Digital Signal Acquisition System
increase the amplitude of MRI signal from tens to hundreds of mV to several Volts
Pre Amplifiers
[MRI System Electronics] Digital Image Processing System includes:
GENERAL PURPOSE MICROPROCESSOR FIELD PROGRAMMABLE GATE ARRAYS (FDGAS)
Digital Signal Controllers
Stream Processor