The engine system has 6 criteria which will put it automatically out of service. They are…?
- major coolant leak
- engine unable to maintain proper temperature (i.e. overheating)
- major oil leak
- low engine oil pressure
- contaminated oil or coolant (oil in coolant, fuel in oil, coolant in oil, coolant in transmission fluid)
- fuel leak
The transmission has 5 criteria which will put it automatically out of service. They are…?
- defective shift linkages
- automatic transmission overheats in any range
- major transmission leak
- transmission will not go into lockup for fire pump operations
- transmission fluid contaminated with coolant
The electrical system has 4 criteria which will put it automatically out of service. They are…?
- alternator not maintaining voltage (not charging)
- battery gassing excessively
- headlights out
- more than 3 emergency lights out
The braking system has 7 criteria which will put it automatically out of service. They are…?
- any audible air leak with park brake released
- any audible air leak with park brake released and service brake applied
- vehicle pulling when brakes are applied
- compressor will not build pressure
- parking brake will not hold truck
- shoes, drums, pads worn beyond manufacturer’s minimum specifications
- shoes or pads with oil contamination
The crew cab has 4 criteria which will put it automatically out of service. They are…?
- broken cab mounts
- cut or broken seat belts
- cracked or broken windshield obstructions (line of sight)
- inoperable windshield wipers
As a group, the chassis, axles, steering/suspension systems, driveline, wheels and tires have 9 criteria which will put the truck automatically out of service. They are…?
- tires cut to cords
- tires with tread depth less than 4/32 on steering axle
- tires with tread depth less than 2/32 on drive axle
- cracked or broken springs
- cracked or broken spring hangers
- loose steering system components
- cracked rims
- missing lug nuts
- major leaks on power steering system
The fire pump has 6 criteria which will put it automatically out of service. They are…?
- pump tests fall below 90% of the original rating of the fire pump, in accordance with NFPA 1911 standards
- pump will not engage manually and/or air/electronically
- pressure control system is inoperable
- pump transmission systems has major leak
- pump panel throttle/pressure control is inoperable
- water tank has major leak
For aerial devices, there are 8 criteria which will put it automatically out of service. They are…?
- power take off will not engage
- stabilizer system inoperable
- aerial device defective
- hydraulic system defective
- cable sheaves defective
- cables frayed
- aerial device structurally deformed or damaged
- torque box/turntable fasteners broken or missing