OCFRD SOPs Flashcards
SOP 070
Leakage of liquid great enough to form drops, but not enough to cause drops to fall from the item being inspected
Class 2 Liquid Leak
SOP 070
Leakage indicated by witness of discoloration, not enough to form drops
Class 1 Liquid Leak
SOP 070
Leakage of liquid great enough to form drops that then fall from the item being inspected
Class 3 Liquid Leak
SOP 085
The practice of being relieved early will occur for calls for service between the hours of
0700 - 0730
SOP 085
The individual receiving the early release will not be allowed to leave the work sit until
0730
SOP 085
Duty personnel shall be present, in uniform, and have all personal safety gear at their assigned apparatus
0730
SOP 085
The drivers of the off going shift will do a vehicle damage inspection of their unit at ______
0725
SOP 085
Shift change takes place at
0730
SOP 085
MDC Login completed by
0745
SOP 085
Apparatus, equipment checks and routine station housekeeping chores should be completed
0930
SOP 085
Reserve apparatus shall be mechanically checked
1000
SOP 085
Beds may be occupied after individual work assignments are completed, between the hours of
1200 - 1300 & 1700 - 0700
SOP 085
Beds shall be stripped and personnel ready to end the duty tour by _____
0720
SOP 085
The station shall be secured
2200
SOP 085
Only OCFRD employees are permitted to be on station grounds after _____ unless approval has been granted by the BC or higher
2200
SOP 085
Monthly Reports Due:
Area knowledge training submitted by
the 25th of the month
SOP 085
Monthly Reports Due:
Assigned monthly PIPs completed by
The last shift of the month
SOP 085
Monthly Reports Due:
Fuel Reports
every Sunday and 1st day of the month
SOP 085
Monthly Reports Due:
EMS Medication Monthly expiration Inventory
15th of each month
SOP 085
Monthly Reports Due:
Station monthly status reveiw
by the 3rd shift of the following month
SOP 093
Marking of Hydrants Bonnet Color:
Class C rated capacity of less than 500 gpm
Red
SOP 093
Marking of Hydrants Bonnet Color:
Class B rated capacity of 500-999 gpm
Orange
SOP 093
Marking of Hydrants Bonnet Color:
Class A Rated capacity of 1000-1499 gpm
Green
SOP 093
Marking of Hydrants Bonnet Color
Class AA Rated capacity of 1500 gpm or greater
Light Blue
SOP 093
The barrels of private hydrants are suggested to be
Red
SOP 093
Hydrants served by reclaimed water system color?
Purple
SOP 093
Public hydrants barrel color
Silver
Red
Yellow
SOP 137
Nitrogen Dioxide (NO2), high level alarm
5 ppm
SOP 137
Nitrogen Dioxide (NO2), low level alarm
1 ppm
SOP 137
Carbon Monoxide, high level alarm
200 ppm
SOP 137
Carbon Monoxide, lower level alarm
25 ppm