Obturation Flashcards

1
Q

2 things preparation does

A
  1. facilitates cleaning

2. controls movement of warm gutta percha

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Why cant leave canal open?

A

superhighway, not 100% sterile

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

which condensers used

A

5/7 and 9/11

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Correct sealer consistency rule?

A

1” draw for 10 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Gutta percha tip size correlates to?

A

tip correlates to file size

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Sizes for non-standardized

A

med and fine-med, tip not sized

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

3 determinants for cone fit

A

visual, tactile (tugback), radiographic (distance from apex)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

2 conditions for tugback?

A
  1. reaches full dist

2. only tugback at apex

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Objective of continuous wave technique?

A

carry a wave of warm gutta percha along legnth starting coronally and ending in apical cork

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Hot tip inserted to within what dist of working length?

A

5-7mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Backfilling done with? Use what needle?

A

hot shot, 23 guage

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

3 steps of backfilling?

A

Insert, inject, condense

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

4 steps of hot tip

A

heat cool remove condense

How well did you know this?
1
Not at all
2
3
4
5
Perfectly