Normal Procedures pt.1 Flashcards

1
Q

SOP - Right engine starting (battery) - (9):

A
  1. “Clear right” Right ignition and engine start - on, [R IGNITION ILLUMINATED] & [R FUEL PRESS] - EXTINGUISHED
  2. N1, fuel flow zero, oil pressure rising.
  3. N1 stable or max N1, min 12%, and ITT below 200: Right condition lever low idle
  4. Fuel 80 - 110 PPH
  5. ITT light up, ITT rise within 10s, and monitor max 1000 celsius.
  6. At 50% N1 or above, right ignition and starter - off.
  7. Note max ITT.

Once engines is stable:

  1. Right condition lever - high idle.
  2. Right gen reset then on. R DC GEN extinguished, check loadmeter, and check battery volt.
  3. CHG battery until generator load is below 50%.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What does “engine stable” after start mean?

A

a. ITT less than 750
b. Torque not powered
c. Prop RPM stable
d. N1 low idle 52%
e. Fuel flow normal
f. P/Ts in the green

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

SOP - Left engine starting (gen assist as per SOP) - (13):

A
  1. Right generator - off
  2. “Clear left” Left ignition and start - on, [L IGNITION ILLUMINATED] & [L FUEL PRESS] - EXTINGUISHED
  3. N1, fuel flow zero, oil pressure rising.
  4. N1 stable or max N1, min 12%, and ITT below 200: Right condition lever low idle, right generator - on, right DC GEN extinguished.
  5. Fuel flow 80 - 110 PPH
  6. ITT light up, ITT rise within 10s, and monitor max 1000 celsius. And monitor
  7. At 50% N1 or above, left ignition and start switch - off.
  8. Note max ITT
  9. Once stable, both condition levers - low idle.
  10. Right generator - off (R DC GEN annunciator extinguished)
  11. Left gen - reset, then on. check load and volts.
  12. Right generator - reset then on. L&R load-meter 10% parallel.
  13. Inverter 1 & 2 individually select and test (380 - 420hz, 110 -120v)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Oxygen Systems Check (N-10):

A
  1. Pax manual drop-out - push off
  2. System ready - pull on
  3. Oxygen masks - check (a. check continuous flow with emergency position, then to 100% position.
  4. Determine duration.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q
A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly