NATURAL GAS ADDENDUM 2...MSA ALTAIR Flashcards
AND SENSIT
MSA ALTAIR DIGITAL issued to …
ALL ENGINE AND LADDERS
-must be used in conduction with SENSIT TKX DETECTOR
TWO SENSOR…
natural gas and oxygen
can detect other gases, but NOT accurate and SHOULD NOT BE USED to detect other gases
BEFORE turning meter on, member must be..
AREA FREE OF CONTAMINATION
When meter is powered on it will run self -check test for
40 SECONDS
-(during this test, meter will activate all 3 alarms, AUDIBLE, VISUAL, VIBRATING)
When screen displays “FAS” (FRESH AIR SETUP”, press POWER BUTTON AGAIN..
- ensure meter is in free contamination area
- this will ‘ZERO’ out LEL sensor
- bypass FAS by pressing rise (right arrow or ^) button or waiting 10 seconds
While air monitoring meter will…
vibrate and flash green LED light every 30 seconds
IN FRESH AIR, normal readings are ..
LEL-0%
O2-20.8%
METER ALARMS AT..
LEL-10.0%
O2-23.5%(OXYGEN enriched)
O2-19.5%(oxygen deficient)
–after alarm activation, use additional meter to verify readings
-to silence alarm, press reset button (right arrow ^)
Meter should be…
stored and charged on apparatus
-if charger malfunctions, use 110 volt adapter
When meter is OOS , OFFICER should notify..
HAZMAT OPS by phone
- one for one
- no unit markings on meter
- meters NOT sent through bag
When atmosphere is above 100% LEL…
LCD symbol XXX will be displayed under the COMB/EX
ALSO
METER WILL ENTER INTO LOCK ALARM STATE–SHUT DOWN LEL SENSOR AND NO LONGER READ NATURAL GAS LEVELS
to reset sensor, meter must be removed to fresh air and turned off then turned back on
in an OXYgen Deficient atmosphere…
-the LEL SENSORs will not be accurate..
normal O2 - 20.8%
LOW O2-19.5%
Upon activation of oxygen sensors, members must.don SCBA FACEPIECE and notify IC of abnormal readings
-notify dispatcher of conditions and have utility company respond, requesting ETA
OXYGEN ENRICHED…
HIGH SENSOR-23.5%
-decrease flashpoint of combustibles and increase chance of ignition of material
series of 3 +++ under O2 ICON indicates atmosphere is above 30%
-extremely dangerous because actual readings are not known
SENSIT TKX COMBUSTIBLE GAS DETECTOR carried by all…
BATTALIONS, HAZ MAT CO 1, HMTU, RESCUE , LADDER (does not mention squad/engine…NEW)
- provides “GEIGER COUNTER” like ticking sound that INCREASES FREQUENCY when gas source as low as 20 ppm of METHANE detected.
- lithium ion battery
- INTRINSICALLY safe
- NOT detect CO
- RECHARGE 2 to 5 hours /LED GREEN FULLY CHARGED
- 20 hours continuous life
- LED blinks green , must recharge, IF AFTER 5 HOURS THERE IS NO SOLID GREEN, NOTIFY HAZMAT
OPERATION OF SENSIT…
-USED in conjunction with ALTAIR
-turn the tick adjust dial FULLY COUNTERCLOCKWISE
-in NON -contaminated atmosphere, slide power on , GREEN LED will illuminate
-red LED may flash and tick may sound during warm up, to silence tick , rotate FULLY COUNTER CLOCKWISE
-UNIFORM ticking should indicates fully warmed up/red LED will also begin to flash
INCREASE IN TICKING SOUND AND FLASHING OF LED INDICATES YOU ARE APPROACHING LEAK
- DECREASE IN TICKING AND DECREASE IN FLASHING LED indicates you are moving away from the leak
- replace with HAZMAT/ONE FOR ONE