Emergencies 3-BASIC EMERGENCIES Flashcards

1
Q

CLOCKWISE…used to close, makeup or TIGHTEN the following:

A
Water valves in faucets (usually)
screws
nuts
pressur cylinders /oxygen/propane
sprinkler systems, water mains
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Counterclockwise?

A

hydrant operating nut CLOSE

hydrant STREET SHUT OFF CLOSE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Toilet Bowl leaking?

A

ball in water tank raised to stop flow

Or

under tank- shut off handle …turn clockwise

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Leaking sink?

A

handle under sink/clockwise

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Removing Toilet Bowl, will provide?

A

Drainage

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Location of WATER SHUTOFF?

A

A. sometimes shut off is located on the wall near the ceiling of the apartment directly below

B. shut off are also located on the riser line of apartments in basements

C. Where MAIN ENTERS BUILDING: usually near FRONT BUILDING WALL(often in corner)

  • COLDEST pipe in building and may have CONDENSATION on outside
  • listen for sound of running water
  • feel VIBRATION
  • look for ARMORED GROUND CABLE which may be attached to main from electric meter
  • once valve is located shut off clockwise

HOUSE MAIN:
-MALLEABLE PIPe -strike with maul or flat head axe or insert round end of stick , chock , pencil

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Flooded Roof:

NEVER CLEAR BLOCKAGE WITH HANDS

-use as FEW MEMBERS AS PRACTICAL on the roof

each sq ft over 12” deep, weighs 62 pounds

A
  • DO NOT clear any blockage with hands! (suction pressure can be high)
  • clear blockage with 6 foot hook or applicable tool from drain or scupper
  • USING HOSE: -stretch entire length under water and allow to fill
  • KINK one end
  • drape over edge over parapet extending below roof level
  • release kink

booster line to roof- charge line and open nozzle/place under water/shut down pumps and disconnect line at street /allow to drain

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Hydrant Shut down:

A

operating nut= counterclockwise

STREET SHUT DOWN- remove plate

  • clean out debris with water
  • wrench on fitting (counterclockwise 17 times)

note: nut usually found off center on street side of the chamber….about 12 turn will be noticeable decrease in flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Steam Leak Radiator- Safety valve blown off:

A

shut down radiator flow at valve handle turning clockwise

REPLACE safety valve or use tapered wooden plug wrapped in cloth…tap in until secure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Flow valve Blown off (radiator)…

A

-genrally it will be nearby and undamaged
-make sure flow handle is in OPEN POSITION (IMPORTANT)
-replace fitting by turning nut on clockwise
NOTe: wear GLOVES..place towel over main valve to divert steam flow while resetting valve
-after restoration of flow valve it may be turned off or on as necessary —may use compound or sealant on threads

Note: may be necessary to shut steam off at boiler

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Overhead Electrical Service Emergencies:

A

treat downed wires as LIVE until an ON SCEEN UTILITY COMPANY REP CONFIRMS that wires have been DE-ENGERGIZED…there is NO SAFE WAY for FD personnel to move energized power lines, even if it presents a condition imminently dangerous to life

members SHALL NOT TAKE ANY ACTION relating to removing electrical wires from people/vehicles until wires are de-energized by UTILIY COMPANY

DO NOT attempt to remove OCCUPANTS from vehicles in contact with wires until UTILITY COMPANY DE-ENERGIZED WIRES

DO NOT ATTEMPt to use hook or rope

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Wires down IN THE STREET….immediately upon confirming that live electrical wires are down and are creating a situation that places human life in danger:

LIFE HAZARD

A

contact dispatcher via Dept. radio indicating life is in danger…specify location -ADDRESS/POLE NUMBER of downed wires..request forthwith POWER REMOVAL AND PRIORITY RESPONSE BY UTILITY COMPANY
-request Response of BC (BC will contact Utility Company Electrical Operations Center directly)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

LIVE WIRES and NO imminent life hazard?

A

guard against hazards of fallen wires by ISOLATING AREA, notify UTILITY COMPANY and standby until a utility crew responds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

In either situation( A. lives wires-life hazard/B. live wires-NO life hazard)…

A

Immediate notification to dispatch/Priority utility response

  • ISOLATE AREA
  • keep apparatus away
  • check nearby buildings for heat at fuse box/electrical service entrance box/utilize TIC
  • caution civilians in vehicles with live electrical wires over it to REMAIN in vehicle until de-energized by utility company
  • stretch line with FOG NOZZLE..keep at least 25 feet away from any downed wire while operating this handline

**DO NOT OPEN HOUSE SERVICE (heated wires can generate CO)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

FALLEN or hanging wires are NOT to be moved by members..

A

Ground immediately near a fallen wire may be energized

  • do not place WEIGHTED OBJECTS on wires
  • do not open house service
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Overheated Ballast:

A
  • identify : smoke/smell/flickering light/presence of heat/darkening of bulb
    actions: shut off power/remove bulb/remove cover panel/DISCONNECT wires to ballast (black box) and remove same/isolate black and white power wires and cover exposed ends with caps or tape/check for fire /smoldering in ceiling/fluorescent ballasts may leak PCB contaminated oil…SCBA must
17
Q

Oil Burner

A

heavy odor /visible smoke usually caused by DELAYED IGNITION
actions
Electrical power:
1. shut off electrical power by oil burner REMOTE CONTROL (RED)…GENERALLY located:
a. PD- top of interior stairs
B. OLT/brownstone/frame- top of stairs. NOte: listen for sound of burner going off, as switch could be for lights

C. NLT- OUTSIDE OF OIL BURNER ROOM

  1. FUSE BOX-box usually marked oil burner
  2. Ignition component at oil burner

other option: FUEL SHUT OFF…at tank (ALL TANKS have shut off ) or at burner (with 275 gallon tank)or on preheat or #6 oil (turn gas off and electric)

*oil burners with larger than 275 gallon tanks, may be shutoff on feed line near filter

18
Q

Gas Leak Stove:

A

check stove is not on

-stove of- turn butterfly PERPENDICULAR to flow of gas pipe (1/4 turn)

19
Q

Burglar Alarms:

A

Silence by:

  • locate alarm and insert wad of paper, chock, match book cover, between clapper and bell
  • disconnect power
20
Q

Ring Removal:

A

soapy water as lubricant

  • finger may be cooled which will decrease swelling
  • ring cutter- less than a minute

stainless steel ring (may need to use PLIERS), ring cutter will not cut stainless steel

21
Q

FISH hook removal …

A

barb NOT embedded..back out HOOK
barb embedded, have pHYSICIAN REMOVE IT
note: medical aid not available, push hook through until barb protrudes, cut the hook at barb or shank and remove it

22
Q

SULFUR candles..

A

-use to discourage vermin and fumes produced are HIGHYL irritating

oPERATIONS:

  • use has
  • few members as possible (OFFICER AND ONE FF)
  • vent as you search
  • candle found, extinguish or remove to outer air
  • wait outside apt. for sufficient time to establish fact the no other candles remain
  • candles usually found on floor in a saucer of water
23
Q

WHEELCHAIR LIFTS on NYC transit buses…

A
  • all NYCTA buses have these lifts
  • if lift malfunctions and traps disabled passenger on lift or inside bus, NYCTA BUS MAINTAINER will be dispatched to repair lift

PROCEDURE:
–KEYED switch at BUS DRIVER’S seat that supplies power to the WHEELCHAIR LIFT AND keyed switch located on WHEELCHAIR lift that activates lift MUST BE IN OFF POSITION AND KEY REMOVED before operations commence.

-ensure wheelchair lift is secure, chocked, stabilized