NATOPS Fuel Flashcards

1
Q

The fuels system is a

A

Crashworthy, suction type, with a self sealing tank (lower 1/3)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The main fuel tank capacity?

Left side components?

Right side?

Interconnect?

A

Has a capacity of 590 gallons (4012 lbs of JP-5).

  • refueling, 2 high level shutoff floats, check valve, sump drain and a vent
  • 2 check valves, sump drain, vent, APU fuel line, and fuel dump system

270-600 lbs each side

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Capacity of Aux Tanks?

PUMP/VALVE FAIL caution?

AUX FUEL TRANSFER FAULT?

A

120 or 113 gal each

Single valve or pump failure, the other valve or pump will pick up.

Total failure of both xfer/shutoff valves, dual transfer pumps, or FMCP logic

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

During xfer of aux fuel if right cell fills faster than left you should

A

Monitor closely, if difference persists stop before right cell is full (approx. 1700lbs.)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Do not initiate unmonitored manual transfer to the main tank from the aux tanks until the Main tank is below _________.

A

3200 lbs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Emergency jettison of external fuel tanks via the ALL STORE JETT pushbutton is inhibited when?

A

Tank has less than 40 gal (272 lbs). SEL JETT must be utilized if below 272 lbs. (This means you will have to do it at 300lbs or less since the fuel gauge only reads in 50lb increments.)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Tank fuel sequence?

During automatic transfer?

A

Main - right ext - left ext

Left - right (reverse of fill)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

At AUTO, the Fuel management logic will not begin until the Main fuel tank depletes to approx _______.

A

2640 lbs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the minimum fuel dump rate?

A

approx. 800 lbs per minute

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Can you dump fuel on ground?

A

Yes. Not protected by WOW.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

If there is a ____ pressure differential, the HIFR will stop fueling.

A

20 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

During HIFR if the right cell fills faster than the left cell you should

A

Monitor closely, if it continues stop fueling before right cell is full (1700 lbs)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What may the #1/#2 FUEL PRESS caution indicate?

A

Possible malfunction of the engine-driven fuel boost pump or an air leak in the fuel system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

When do you perform the Manual Fuel Transfer Check?

A

When main fuel tank capacity has decreased approximately 300lbs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

When you put the MASTER switch to REFUEL, what does the sequencing logic keep on?

A

the Precheck switches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What does a Black BITE mean?

White BITE?

A

Go condition

NO GO condition

17
Q

What is prevented if you have a malfunctioning FMCP (with electrical power applied) causing activation of the precheck valves?

How can you correct this?

A

This prevents the ability to pressure refuel or HIFR

The FUEL MGMT CB on the COPILOT CB panel must be pulled to allow fueling

18
Q

How do the fuel probes work?

A

They are capacitance-type sensors that employ fuel as a dielectric to measure the weight of the fuel in each tank.

19
Q

When will a FUEL LOW caution appear?

A

When a fuel cell reaches 300lbs

20
Q

Fuel will dump from a dump port in the right fuel cell down to what?

A

The low level sensor, approx 300lbs per side

21
Q

How do you dump from the external tanks?

A

You have to set the FMCP MASTER and MODE switches to TRANSFER and MANUAL OVRD, then selec the FUEL DUMP switch

22
Q

Can you dump the main tank when the FMCP is in STOP FLOW?

A

yes

23
Q

What is the pressure of the pressure Refueling system?

A

55 psi

24
Q

Why is there a delay while refueling if you have a left external tank but not a right external tank installed?

A

Due to the FMCP logic determining that there is no right tank to fill

25
Q

How do you know there is a malfunction in the refueling system?

A

If full fuel flow continues while the precheck valves are being held in the precheck condition