What is another name for “Zone Cabling” as per the Data, Voice and Video Cabling textbook? *
Horizontal cabling
What is the name of the tool shown in the image below? *
https://lh6.googleusercontent.com/qjqIjv8QB8oALUkJuU3-h2gU7l6xgFrGYkqSVynQ-6QkktSKXXqKHcm3x3zlh5sM-6_J_Vwo_vUDTmYvq8aC6XRXZ7nv5M20Mksm7BTsa4NfwEtpwmueTDraUvxriYeM2g=w395
Fish tape
What is the name of the tool shown in the image below? *
https://lh5.googleusercontent.com/VCjlutQuZt3Zf4PxpbIJTODyTnp6EY2X63Y3u-o7OgazpKam30ZjBWaGYIemSde7gm-wmXG29mTtwXX_KZFaUH2lFhC5Lyfp5nFoKjAB3y0Ha-jTsowHvjve7XDEiGACtQ=w387
BIX 16A Punchdown Tool
The ANSI/TIA/EIA 607-A standard specifies that a unique number is to be used for each network cable that is being installed. *
False
The White/Orange pair in a 200 pair cable wrapped with a Red/Green binder ribbon would be pair number what in the entire cable? Example Pair XXX *
Pair 177
Assuming the hardware you used is compatible with the type of UTP cabling installed what would be the easiest way to correct a “NEXT” error should it be displayed on the certification meter while testing? *
Re-terminate the connector ensuring that the twist ratio is within specification
When you finish a cable installation the customer expects it to work and so do you. Which of the following tests performs basic continuity functions and are the first line of defense in finding cabling problems. *
Verification test
Which of the following project phases would normally include cable certification? *
Finish phase
The following error was displayed on the image below when a cross-over patch cable was being tested. What numbers should the meter have displayed on the bottom line if the cable was made properly? *
https://lh6.googleusercontent.com/8DwC6IzvTXxkAc07IUdakEpDeyKragzMmxRLgU5kIr0gt3YsyATHAJywK_7ZgIa6nsAFZIj3lGkS_2McrBlgMm6jWXUknaf9QSaylxaqinPJCCp8asS2LIxyJXDJ80Me8g=w1279
36145278
What binder ribbon color would identify the pairs 126-150 in a 200 pair cable? Example Black/Green *
The correct answer is: Red/Blue 1-25----------White/Blue 26-50--------White/Orange 51-75--------White/Green 76-100------White/Brown 101-125----White/Slate 126-150----Red/Blue
What TIA/EIA pinout standard is depicted in the image below? *
https://lh4.googleusercontent.com/L9UCwxQoIha7FbujHPlNNDbr5j-5i1Ye5dp-OsJXf32omWMldmK_cByafZJCnl8zfnZkVePbqerWoE6e9nUI4AiaW7v-2_hCBEkIcRQb69WZnUVvHwi3HGJZoTqA_zG0xw=w157
TIA/EIA T568B
You have been asked to install ethernet cabling in an area with very high EMI. What type of ethernet cable should you have used? *
STP
Fred was asked to install some category 6 unshielded twisted pair cabling through a plenum ceiling from the server room to the CEO’s office. Fred found some boxes of cable in the storage room but he isn’t sure if he can use them or not. What’s the easiest way for Fred to figure out if he is using the correct cable? There are four correct responses. *
- Check the cable jacket for the letters CMP
- Check the cable jacket for the letters UTP
- Check the cable jacket for the word SOLID
- Check the cable jacket for the category of cable which in this case is CAT6
Which of the following OSI layers converts the ones and zeros to electrical signals and places these signals on the cable? *
Physical layer
When both ends of a patch cable are terminated identically the patch cable is referred to as a_______________? *
Straight through cable