Module 8 Flashcards
The automatic ________ should be shut off once a patient is positioned for the tangential projection used to display calcifications.
exposure control
compression release
target selector
kVp selector
compression release
The CC from below projection is used:
- in imaging of the male breast
- for women with lordosis
- to help define abnormalities in the upper region of the breast
1 & 2
1 & 3
2 & 3
1, 2, & 3
1 & 3
In most situations, how many images make up an augmented breast study?
2
4
6
8
8
Magnification only can be used with spot compression.
TRUE
FALSE
FALSE
Underexposure is a cause of _______ in mammograms of dense breasts.
false-positive readings
false-negative readings
artifacts
high contrast
false-negative readings
To properly display breast anatomy, the optical density for glandular breast tissue should measure at least _______.
- 0
- 5
- 0
- 5
1.0