The lead time displayed on the quote of an MLI or bridle begins when?
when drawings are approved and returned to VEGA
A liquid SG ranges between 0.60-0.75 normal operation is around 0.70. what SG should the float be designed for?
A low end of the range 0.60
For existing troublesome displaces instruments, which VEGA offering is a great alternative?
A VEGAFLEX guided wave radar using the existing displacer chamber
Lower liquid specific gravity usual result in:
increased float size/lenght
What is the ideal MLI to provide redundant measurement with a single 4-20 mA output?
VEGAMAG 82
Which instrument would you recommend when only visual indication is required?
VEGAMAG81
What are some key advantages of an MLI versus a sight glass?
The process is confined to the sealed chamber
What information is NOT necessary to initiate a VEGAMAG 81 quote?
Dielectric constant
For existing troublesome displacer instruments, the most cost-effective VEGA retrofit would be…
A VEGAFLEX Guide wave radar using the existing displacer chamber
To promote increased personnel safety for high-temperature applications, a simple solution for a Magnetic Level Indicator is…
insulation jacket
When faced with an MLI installation where very little ground clearance will restrict float access, you should consider the following solutions:
Recommend a flange-top, cap-bottom chamber configuration
consider a larger diameter chamber with a shorter float
When collecting information about a customer’s MLI application, the most critical detail you need about a specific gravity range is…
The minimum SG
For cryogenic applications that may experience boiling or flashing liquids, which solutions should you consider?
Enlarged chamber with float guide rods
cryogenic insulation
True or False: When measuring water level in a boiler or feedwater heater, the specific gravity can be reported as 1.0?
False
If a customer requests an MLI that requires a redundant measurement system with a single
4 – 20 mA output, an ideal recommendation would be?
A VEGAMAG 82 with an integrated VEGAFLEX transmitter