Controllers Flashcards

1
Q

How many measured values can be shown on the MET800 series display?

A

3

you can also show the totalizer at the bottom

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How many measurements can be stored on the SD card in the VEGAMET86x?

A

170K

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The new VEGAMET’s are for water and wastewater industry.

A

True

they can be used in other industries but primary for W and WW

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The VEGAMET 862 can power and support how many 4-20 mA HART sensors.

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The new VEGAMETs are considered Signal Conditioners.

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The new VEGAMET 800 series can be commissioned or set up with?

A

Bluetooth

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

VEGAMET Commissioning has Four Golden Rules: Installation/Mounting, Application, Adjustment and

A

False Signal Suppression

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

True or False: The two types of applications most commonly used for VEGAMET’s are Parshall Flume and V-notch Weir.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

In a V-notch Weir, it is recommended that the sensor is mounted at least ____ times the maximum head height.

A

4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Where is the 0 reference point of the PULS C21 and PULS31?

A

Tip of the antenna cover

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The VEGAPULS 69 provides the following features:

A

Non Contact measurement
Non mechanical measurement
Tight beam angle <4degrees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The most meaningful way to determine weight is to transfer known weight of material into a silo and adjust the scale.

A

Certainty (repeatable and reliable)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

A VEGA cellular gateway provides:

A

Ability to configure troubleshoot the measurement devices remotely
the ability to be completely separate from the plant’s network
a wireless connection to the internet for inventory data transmission

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The VIS portal provides easy access to real-time inventory to

A

those with the authorized access (UN and PW)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Not a cementitious material

A

admixture

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

From a logistics optimization standpoint, inventory “certainty” is more important than inventory “accuracy”.

A

True

17
Q

Not a good application for VIS?

A

weight measurement for batching purposes

18
Q

China produced more concrete in 3 years than the US did in the 20th century

A

True

19
Q

The VEGAPULS 69 measures

A

distance

20
Q

Not a good application for VIS

A

High and low level alarming

Operator interface to the plant process

21
Q

How many radars can be connected to a VEGASCAN 693 with the EX output option (Single chamber sensors that must be set to HART Multidrop with unique addresses)?

A

5

22
Q

What is / are the primary function(s) of the VEGATOR 100 Series?

A

Switching and isolation/barrier

23
Q

How many radars can be connected to a VEGASCAN 693 (Single chamber sensors that must be set to HART Multidrop with unique addresses)?

A

15

24
Q

What is the maximum wiring distance for a VEGADIS 81?

A

50m

25
Q

What VEGA sensor communications options are available for most transmitters?

A

4-20mA HART
Profibus PA
Foundation Fieldbus
Modbus 485 RTU

26
Q

What is the maximum recommended distance for Bluetooth PLICScom with the VEGA Tools app or VEGA DTMs with PACTware?

A

25m

27
Q

What does IIoT stand for?

A

Industrial Internet of Things

28
Q

What is the primary function(s) of the VEGATRENN Series?

A

4-20mA signal transmission and isolation - intrinsically safe power to the switch
Galvanic isolation - separates hazardous area power from ordinary areas
HART repeating isolation barrier

29
Q

What software solution do you recommend for a customer who wants to monitor 12 tank levels and trend the history? The customer would also like to have notifications of low and high levels.

A

VIS

30
Q

Which controller is used with a VEGASWING 61 with mA step-change electronics so the customer does not have to perform the annual wet test? (Note: The wet test is the customer having to physically remove the sensor(s) and perform a bench test once a year.)

A

VEGATOR 121 or 122

31
Q

The VEGAMET 862 can power and support how many 4 … 20 mA HART sensors?

A

2

32
Q

What is the only way that the new VEGAMET 800 series controllers can be fully commissioned?

A

Bluetooth

33
Q

Customers can access the HTML webpages in the VEGAMETs and VEGASCANs with Ethernet communication options via which web browser(s)?

A

IE, Chrome, firefox (mozilla)

34
Q

How many measured values can be displayed on the new VEGAMET 800 series display?

A

3

35
Q

What is the VEGA communicator that connects to a laptop or PC via USB and is used to commission most VEGA sensors with VEGA DTMs and PACTware?

A

VEGACONNECT

36
Q

NOT a good use of the VEGA Inventory System?

A

For accurate weight measurement for batching purposes