Metro SOG 13 - Sheet1 Flashcards
From Metro SOGs:
WMD
weapon of mass destruction
From Metro SOGs:
CB-EMIS
Chemical Biological Emergency Management Information System
From Metro SOGs:
Chemical Biological Emergency Management Information System is a resource available to the IC
Identify activated sensors Obtain train movement Gather weather info and local monitoring station Monitor video from metro Access dispersion and plume cloud models
From Metro SOGs:
Where are Flammable Vapor and Gas Detection are located?
located in likely areas that enter the metro. Those flammable vapor types are gasoline, LPG and natural gas.
From Metro SOGs:
Are all ventilation shafts protected by detection
Only those not protected by a raised curb around the opening will be in the base of the shaft.
From Metro SOGs:
Where are these detecter system located?
Every 800 feet along with the ETS boxes and at right-of-way gates.
From Metro SOGs:
Where are the tunnels sensors located?
located in the lowest portion of tunnels were gas or vapor is likely to accumulate.
From Metro SOGs:
What are some priority for locating detectors?
Where vehicle traffic and accident spills Flammable liquefied gas is stored or used Detection system calibrated at 20 percent lower flammable limit (LFL)
From Metro SOGs:
How many unit are assigned to a Metro Hazardous Material CB-EMS?
3-Engines 1-Truck 1-Special Ops BFC (IC) 1-firefighting Division BFC (metro liaison at OCC) 1-Rescue squad 1-HazMat unit 1-EMS Supervisor 1-Medic unit 1-Basic unit 1-Safety officer
From Metro SOGs:
Resources availably to assiset with Metro Hazardous Material CB-EMS?
Hazmat task force Mass Casualty task Forces Additional EMS unit Additional fire suppression
From Metro SOGs:
Item that the first responder adhere to the hazardous material?
Recognition Identification Notification Isolation Protection
From Metro SOGs:
What is the location for all unit exept who?
exception of the first due engine will stage two blocks away in line of approach with level III accountability, unit should stage uphill, upwind, and used building for shielding
From Metro SOGs:
Who’s does the IC contact and speak to whom on a metro Hazmat call?
Immediately contact metro CC on (202) 962-1652 (primary) (202) 962-1970(secondary) speak with the assistant superintendent on duty
From Metro SOGs:
First Due Engine responeability is to?
stop their apparatus at the base location to view the incident
From Metro SOGs:
First Due Engine should cautiously do what?
All members with the exception of the driver is to cautiously and in a defensive mode approach the incident, with full PPE including SCBA and donned, to exposed to potentially contaminated victims or had to enter the hazard zone to perform an immediate rescue of a viable victims.