Memory Items Flashcards
1
Q
Runaway Stabilizer
A
- Control Column…………………………………..Hold Firmly
- Autopilot (if engaged)………………………..Disengage
- Auto throttle (if engaged)…………………..Disengage
- Control Column & Thrust Levers……….Control aircraft pitch attitude & airspeed
- Main Electric Stabilizer Trim………………Reduce control column forces
- If the runaway stops after the autopilot is disengaged………Do not re-engage the autopilot of autothrottle
- If the runaway continues after the A/P is disengaged………..Stab Trim Cutout Switches (both)………………………………………Cutout
If the runaway continues:
Stabilizer trim wheel……………………………….Grasp and hold
2
Q
APU Fire
A
- APU Fire Switch………………Confirm…………..Pull, rotate to the stop and hold for 1 second
- APU switch……………………………………………….Off
3
Q
Airspeed Unreliable
A
- Autopilot (if engaged)…………………………………Disengage
- Auto throttle (if engaged)…………………………..Disengage
- F/D switches (both)…………………………………….OFF
- Set the following gear up pitch attitude and thrust:
Flaps Extended……………………………………………….10° and 80% N1
Flaps Up…………………………………………………………..4° and 75% N1
4
Q
CABIN ALTITUDE WARNING or Rapid Depressurization
A
- Don oxygen masks and set regulators to 100%
2. Establish crew communications