To Open the Recirc Sump valve ICM-305, what alignment must you have?
Can’t go onto recirc sump unless your isolated from the RSWT via RHR and CTS suctions
To Open the CCP or SI pp Suction from the RHR Pumwhat alignment must you have?
Can’t supply the CCP or SI pump with water from RHR pump unless you’re on the recirc sump and the SI pump recirc back to the RWST is isolated bc you’d pump your recirc sump to RWST
To open RHR Spray valves, what alignment must you be in?
Must be on recirc sump
To Open your RHR pump suction valve, what alignment must you have?
Can’t be on the recirc sump, trying to Spray, or trying to supply CCP / Si with water from RHR
What is the normal position for RWST Valves to CCP Suction IMO-910 and 911 and what auto opens them?
Parallel, normally-closed, motor-operated Automatically open on SI signal Automatically open on Refueling Water Sequence: low-level (2.5%) in VCT
How to the CCP Emergency Leak-off Valves (ELO) QMO-225 and 226 work on a SI?
Close on SI signal Open after2 sec time delay with SI signal present and RCS pressure above 1825 PSIG. Close if RCS pressure drops below 1812 PSIG
CCP Emergency Leak-off Valves (ELO) QMO-225 and 226 continue to cycle on pressure after a SI until?
SI signal is reset Control switch placed in PULL TO RESET position - resets SI seal-in circuit
East CCP Emergency Leak-off Valves QMO-225 receives pressure signal from
NPP-151
West CCP Emergency Leak-off Valves QMO-226 receives pressure signal from
NPP-153
IMO-340 East RHR HX to Charging Pumps Suction Supply Normal Position and Purpose?
Normally closed Aligns RHR pump discharge to CCP suction header
When is IMO-340 East RHR HX to Charging Pumps Suction Supply Open?
Open for cold leg recirculation
What are the interlocks with IMO-340 East RHR HX to Charging Pumps Suction Supply in order to open this valve ?
ICM-305 Recirc Sump Suction must be Opened and have control power IMO-262 OR IMO-263 SI mini flow must have control power and be closed
What are Recirc Sump to RHR Suction Valves ICM 305 and 306 Interlocks?
Will not open unless RHR Suction from RWST Iso valves are closed (IMO-310 and 320) AND CTS suction from RWST Iso valves (IMO-215 and 225) are closed.
What are the interlocks with IMO-350 West RHR HX to Charging Pumps Suction Supply in order to open this valve ?
ICM-306 Recirc Sump Suction must be Opened and have control power IMO-262 OR IMO-263 SI mini flow must have control power and be closed
What are the interlocks for IMO-330 and 331 RHR to Upper spray header to open?
Recirc sump isolation valves ICM-305 and 306 must be open