Loss of secondary Flashcards
Sources of water for secondary
- Cst
- other unit cst
- esw
normal secondary pumps available
- hotwell
- condensate booster
- mainfeed pumps
Pumps available for trip
- Tdafp
- mdafp
- hotwell
- condensate booster pump
3 methods to remove heat from the core
- transfer heat to mainfeedwater via steam generator
- transfer heat to ccw via rhr hx
- transfer heat to containment atmosphere via pzr porvs
least desirable method to remove heatr from the core
feed and bleed via the pzr porvs
it creates a loca in containment
PRT rupture disk setpoint
what valve do we use to crosstie CST’s
12-crv-51
Aux Feed Tasks
- locally reset TDAFP
- local operation of afw feed valves
- cross tie with other unit
AEO tasks if we cant restart feedwater pumps
why do we trip RCP’s when attempting to restore main feedwater
SG safety setpoints
- two at 1065
- two at 1075
- one at 1085
how much reactor power is each safety rated for
Steam Dump Trips
- Low vacuum (20.6 inches)
- no circ water pump breakers closed
- crid 2 de-energized
what pressure are the sg porvs set at
how much reactor power is each porv rated for
2.5%
In what order would we recover from loss of feedwater supply
- aux feed pumps
- aux feed with other cst
- other unit cst and aux feed pumps
- restart main feed pumps
- feed through main feed flowpath with condensate booster pumps
how would we recover from loss of steam dumps
bleed out of the porv
what if we cant restore feed water
feed and bleed eccs supply to pzr porv to prt to containmnet