Loss of IA Flashcards

1
Q

What are entry conditions for Loss of IA?

A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

When will unit 1 terminate cross connect with Unit 2?

A

U1 IA header pressure < 60 psig.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What actions are taken if IA reaches 60# and lowering?

A

Commence plant shutdown at CRS directed rate, CV-1206 in override, if PZR level not maintained > 100” open HPI block.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What actions are taken if IA pressure reaches 35 psig and lowering?

A

Trip the reactor, actuate MSLI and EFW and isolate L/D.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How do makeup and purification valves fail?

A

CV-1222 - as is

CV-1235 - as is

CV-1207 - open

Di inlets and MU filter inlets - closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What position do FW and Steam valves fail (SU,LL,TBV,ADV)?

A

SU valves - as is

LL Valves - as is

TBVs/ADVs - Closed, but steam pressure will force valves open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What position do ICW Discharge/suction cross connects fail?

A

Closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What actions are taken if PZR level reaches 290”?

A

Close CV-1206, Makeup Blocks, Secure OP HPI pump if ICW available to seal coolers

If ICW not available, then prior to reaching 290” trip rx, actuate EFW, close CV-1206, trip RCPs and bottle up seals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly