Loss of IA Flashcards
What are entry conditions for Loss of IA?
When will unit 1 terminate cross connect with Unit 2?
U1 IA header pressure < 60 psig.
What actions are taken if IA reaches 60# and lowering?
Commence plant shutdown at CRS directed rate, CV-1206 in override, if PZR level not maintained > 100” open HPI block.
What actions are taken if IA pressure reaches 35 psig and lowering?
Trip the reactor, actuate MSLI and EFW and isolate L/D.
How do makeup and purification valves fail?
CV-1222 - as is
CV-1235 - as is
CV-1207 - open
Di inlets and MU filter inlets - closed
What position do FW and Steam valves fail (SU,LL,TBV,ADV)?
SU valves - as is
LL Valves - as is
TBVs/ADVs - Closed, but steam pressure will force valves open
What position do ICW Discharge/suction cross connects fail?
Closed
What actions are taken if PZR level reaches 290”?
Close CV-1206, Makeup Blocks, Secure OP HPI pump if ICW available to seal coolers
If ICW not available, then prior to reaching 290” trip rx, actuate EFW, close CV-1206, trip RCPs and bottle up seals