Loss Of Electrical Supplies Flashcards
Changeover switches have two positions they are ?
Normal
Alternative
Dchq will manage the restoration of electrical supplies by ?
Identifying the necessary changeover switches/ MCCB
Briefing personnel
Ensuring changeover switches/ MCCB are manned
Making warning pipe
Starting another electrical audit when chnageover / MCCB switches are made
Hazards of reenergising previously deenergised AC and DC electrical equipment ?
Electric shock
Machinery may start, move or have an undiagnosed fault condition.
The electrical audit card has the following info on it ?
Audit number and location
Audit type
A numerical list of electrical equipment or lighting
A tick box if equipment has failed
Name of auditor
Time of audit
Who can complete electrical audits and how long do they have to complete them ?
Any one and they have are to be completed within 3 minutes
After you have completed an audit what are you to do ?
Return card to DCHQ
If unable to return card to Dchq pass on info via Damage control net or WE net or telephone
Dchq documentation allows the WE cell to manage the situation as it hold info on ?
Tiger team personnel
Tiger team location
Closing up checks
MCCB dumps
Fwd changeover switches positions
Spare load centre MCCB
Electrical audit cards
Electrical kill cards
How many people in a tiger team and how are they identified ? Who do they always maintain comms with
Always in pairs and they are identified by coloured surcoats/ armbands
Dchq
Contents of a tiger teams bag ?
Test equipment and tools
Kill cards and electrical composites
Dchq consists of ?
Dco
Me cell - DCMEO
ME mechanical
ME electrical
WE cell - DCWEO
WE sensors
WE weapons
Incident board marker
Comms number
Once the cause of an electrical supply loss has been identified it should be isolated from the electrical distribution system to ?
Prevent further loss
Allow the maintainer to investigate
Restore electrical supplies
Likely causes of main electrical supply failures
TGs
MSCs
DGs
Main breakers
Load centre breakers
Moulded case circuit breakers (MCCB)
Shore supply
MRSs priority in an electrical supply loss ?
Identify the source of the failure and inform command/ DCHQ of the electrical systems status. Also make full main broadcasts to inform fwd of electrical supply losses that they may not notice
If sub loses 24V DC supplies what happens ?
Sub is piped to diving stations and systems need to be locally controlled
DC failures can be caused by ?
Battery breakers
MSCs
DC DGs
DC shore supply
Loss of main battery