Lofts Flashcards
Choose the correct construction features of loft bldgs.
A. high ceilings
B. large un-compartmented spaces
C. freight elevators close to front of entrance
D. class 5 construction
A,B,C
1.1
Cast iron lofts built from 1840-1870's can be 7-8 stories in height depths reaching up to 90' & if theres no interior columns what does this indicate? A. spans greater than 20' B. 25' C. 30' D. 35'
B. frontage is usually 25’. indicating no interior columns.
4.1.1
Newer cast-iron bldgs. 1880's-1901, generally have how many stairways & what type? A. 3 enclosed B. 2 u-return C. 3 straight run D. 2 enclosed
D. 2 enclosed w/ a 2 hour fire resistive rating.
4.2.2
T/F: Fireproof lofts range from 10-15 stories, rectangular dimensions 50-100’ wide, & 75’- 200’ deep, some can even span an entire block.
TRUE.
4.4.1
T/F: Freight elevators will have fireman service installed.
FALSE.
will NOT
5.1.2
L-159 is relocated to lower manhattan, they receive a phone alarm for an emergency at a loft type bldg. The OVM looks up & sees a sign in the windows that says "shaftway". What does this mean? A. elevator shaft faces the street B. light shaft faces street C. air shaft faces street D. rescue of handicapped people access.
A. any window serving the shaft is required to display a “SHAFTWAY” sign across the outer portion of window.
5.1.2
Prior to 1938 the stairs in these type bldg's. were constructed of wood. Since 1938 what has been done & what must we be cognisant of? A. stairs covered w/ sheetrock, overhaul B. covered in tin/ overhaul C. covered in cast iron/ dont overhaul D. tin/ dont overhaul
B. This area should not be overlooked during overhaul.
5.1.13
After 18 1/2 horrible pages of loft bldg. non-sense you should know that on pg. 19 6.1.1 they finally tell you that what size hose is to be used initially? A. 1 3/4 B. 2 1/2 C. 3 1/2 supply for T.L D. non of the above
B. 2 1/2
6.1.1
E-308 E-309 E-290 TL-159 L-103 are the 1st units to a cellar fire in a loft bldg. This bldg has a srinkler system protecting the cellar. Who is to supply it in the event E-308 can't? A. 290 B. 309 C. 159 D. 4th engine on the 10-75
B. The 2nd engine supplies it if the 1st couldnt do it. this is true as well for sub-cellars.
6.2.1
With the same assignment as in previous question, who ensures sprinkler is fed if it services the fire area on the 3rd floor? A. 290 B. 309 C. 159 D. 103
A. 3rd due engine ENSURES.
6.2.2
If the fire is on the 14th floor who ensures sprinkler is fed? A. 309 B.290 C. 308 D. 103
B. 6.2.3
Prior to proceeding above the fire the 2nd due truck boss must communicate his intentions to whom? A. IC B. 2nd engine boss C. bosses on fire floor D. 1st truck boss/IC
C. in order to be warned of any situation necessitating withdrawal.
7.1.11
When sprinklers are manually shut down who if anyone must remain at the shut-off in case the system needs to be reactivated? A. can-man B. control ff (2nd due) C. div. aide D. anyone
D. A member
7.1.17
Do you agree/disagree w/ L-103’s 1st due roof man taking the aerial to get to the roof of loft type bldg in a row of other loft type bldgs.?
DISAGREE.
Adj.bldg., Aerial/TL, fire Escape
AATE
7.2.1 D1
E-309 E-308 E-290 TL-159 L-103 are assigned for a fire on the 3rd floor of a 6 story loft w/ straight run stairs. Who notifies IC of stair type? A. E-309 B.L-103 C. TL 159 D. E-308
B. 2nd truck
7.2.2 A2