What is the purpose of the Liquid waste system?
Collects potentially radioactive liquid wastes and processes them for recycle or discharge from the plant.
How are 12-RRV-255/256 interlocked?
you can not have both closed.
What will cause 12-RRV- 285 to auto close?
Trips from high radiation signal from RRS-1000.
What is the interlock for 1-RRV-286 and 2-RRV-287?
Interlocked to prevent opening unless at least one Circ. pump in operation in that unit.
What are some sources of water to the DWHUT
Open drains from 609’ and above. and the Dirty sump tank.
What are some sources of water to the Dirty Sump tank?
Open drains form 587’
What are some sources of water to the CWHUT?
Hard piped drains from the 609’ and above. and the Clean Sump Tank.
What are some sources of water to the Clean Sump Tank?
Hard piped drains from 587’