Limitations (Air Bleed/Cond/Press/Vent) Flashcards
With passengers on board, it is not recommended to exceed ____ min without air conditioning supply.
20 min. The lack of fresh air supply will significantly reduce the cabin’s air quality.
The flight crew must not use bleed air from the ____ and the ____ at the same time, to prevent any adverse effect on the Bleed Air System.
APU BLEED and HP Air Start Unit
Time Limitation for Normal Avionics Ventilation System using Aircraft Electric Power Supply, on ground
OAT ≤ 49 °C
No limitation
Time Limitation for Normal Avionics Ventilation System using Aircraft Electric Power Supply, on ground
49 °C ≤ OAT ≤ 55 °C
2 hours
Time Limitation for Normal Avionics Ventilation System using Aircraft Electric Power Supply, on ground
55 °C ≤ OAT ≤ 60 °C
1 hour
Time Limitation for Normal Avionics Ventilation System using Aircraft Electric Power Supply, on ground
60 °C ≤ OAT ≤ 64 °C
0.5 hours
Maximum Positive Differential Pressure
9.0 psi
Maximum Negative Differential Pressure
-1.0 psi
Safety Relief Valve Setting
8.6 psi
The flight crew must not use conditioned air from the packs an from the ____ at the same time, to prevent any adverse effect on the Air Conditioning System.
LP Air Conditioning Unit
Minimum Cabin Altitude Selection
-2,000 ft
Maximum Operating Altitude
39,800 ft
Outflow Valve Closure Altitude
15,000 ft
Maximum Cabin Altitude Selection
14,000 ft
Cabin Altitude Warning Altitude
9,550 (± 350 ft)
Maximum Normal Cabin Altitude
8,000 ft