Lesson 13 and Lab Manual Flashcards
what is the primary cause of near end cross talk?
poor termination field ends
Grade two residential cabling requires a minimum of _____ for each cabled location
two cat 5e and two coax
what is the maximum signal strength allowed at the TVs’s tuner?
15DB
list the primary colors for multipair backbone cable
white red black yellow violet
what is the name of the grey/green plastic box that is mounted to many homes and that serves as a Demarc for the local carrier
NID
network interface device
why is it important to always route multipair backbone cable down one side of the wall fields and across the bottom of the field to enter the terminating blocks
for future expansions. make it easier to add blocks below without damaging cable
why do we use c5 clips for multi pair and c4 for four pair
c4 only fits 4 pair and c5 fits a 5 pair the color scheme would be off
can 4 pair cable be used for backbone? when is this likely
yes, for smaller applications
residential telecommunications cabling standard is
ANSI/TIA/EIA-570-B
what is the maximum length of 5e 6 and 6e?
90 meters plus 10 meters of patch cords
what is the max amount of untwist for cat 3
3 inchs
to comply with the standard modular outlets must be wired according to
TIA/EAI T568-A
What is the purpose of using a multi pair backbone cable?
one pull for multiple circuits. smaller and more efficient
access to the electrical ground shall be provided _____ of the distribution system
within 5 feet
residential structured cabling is designed and installed according to ______ topology
star or home run