Lab 1 Quiz Anesthesia Delivery System Flashcards

1
Q

Which of the following statements is true in regards to non-rebreathing systems?

  1. It contains soda-lime to scavenge CO2
  2. It has less resistance and fewer components
  3. Less gas waste and atmosphere pollution
  4. It is used in patients >10kg
  5. Flow rate is 20-50ml/kg/min
A
  1. It has less resistance and fewer components
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

An E-cylinder contains how many PSI and Liters of Oxygen?

  1. 6600L and 2200PSI
  2. 660L and 2200PSI
  3. 6600L and 750PSI
  4. 660L and 750PSI
A
  1. 660L and 2200PSI
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Which of the following is FALSE when discussing flowmeters?

  1. A flowmeter controls the rate at which a specific gas is delivered.
  2. The oxygen flowmeter should always be first (upstream) in the series of flowmeters to help prevent the delivery of a hypoxic mixture.
  3. Flowmeter tubes are gas specific.
  4. Excessive torque should be avoided when closing flowmeters.
A
  1. The oxygen flowmeter should always be first (upstream) in the series of flowmeters to help prevent the delivery of a hypoxic mixture.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Using the quick flush valve on a non-rebreathing system is a good way to deliver IPPV during general anesthesia.

  1. True
  2. False
A
  1. False
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What oxygen flow rate and breathing system would you use for a 2kg cat?

  1. 100 ml/min and universal F
  2. 600 ml/min and universal F
  3. 100 ml/min and mapleson F
  4. 600 ml/min and mapleson F
A
  1. 600 ml/min and mapleson F
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

A pressure reduction valve reduces cylinder pressure to a fixed:

  1. 50cmH20
  2. 50 PSI
  3. 50 mmHg
  4. 50 L/min
A
  1. 50 PSI
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Which of the following statements is FALSE regarding out of circuit vaporizers (VOC)?

  1. These vaporizers deliver a precise anesthetic concentration of anesthetic vapor
  2. Gas within the vaporizer is split between the bypass and vaporization chamber
  3. VOC’s are agent specific
  4. Output is dependent on temperature and gas flow
A
  1. Output is dependent on temperature and gas flow
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

An “F air” canister would scavenge all of the following agents EXCEPT:

  1. Nitrous oxide
  2. Carbon dioxide
  3. Isoflurane
  4. Sevoflurane
  5. Both A and B will not be scavenged
A
  1. Both A and B will not be scavenged
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Your E cylinder has 900PSI remaining. You currently have your flowmeter set to 3L/min. How many minutes remaining do you have in your tank?

  1. 300 minutes
  2. 200 minutes
  3. 90 minutes
  4. 30 minutes
A
  1. 90 minutes
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Which of the following functions of the oxygen flush valve is/are correct?

  1. Bypasses vaporizer and delivers oxygen directly to common gas outlet
  2. Delivers oxygen to the circle at 35-75L/min
  3. Dilutes the anesthetics gases in the system
  4. All of the above
A
  1. All of the above
How well did you know this?
1
Not at all
2
3
4
5
Perfectly