Key Topic 75: Test Equipment Flashcards

1
Q

3-75L1: How is a frequency counter used?

A. To provide reference points on an analog receiver dial thereby aiding in the alignment of the receiver.

B. To heterodyne the frequency being measured with a known variable frequency oscillator until zero beat is achieved, thereby indicating the unknown frequency.

C. To measure the deviation in an FM transmitter in order to determine the percentage of modulation.

D. To measure the time between events, or the frequency, which is the reciprocal of the time.

A

D. To measure the time between events, or the frequency, which is the reciprocal of the time.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

3-75L2: What is a frequency standard?

A. A well-known (standard) frequency used for transmitting certain messages.
B. A device used to produce a highly accurate reference frequency.
C. A device for accurately measuring frequency to within 1 Hz.
D. A device used to generate wide-band random frequencies.

A

B. A device used to produce a highly accurate reference frequency.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

3-75L3: What equipment may be useful to track down EMI aboard a ship or aircraft?

A. Fluke multimeter.
B. An oscilloscope.
C. Portable AM receiver.
D. A logic probe.

A

C. Portable AM receiver.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

3-75L4: On an analog wattmeter, what part of the scale is most accurate and how much does that accuracy extend to the rest of the reading scale?

A. The accuracy is only at full scale, and that absolute number reading is carried through to the rest of the range. The upper 1/3 of the meter is the only truly calibrated part.

B. The accuracy is constant throughout the entire range of the meter.

C. The accuracy is only there at the upper 5% of the meter, and is not carried through at any other reading.

D. The accuracy cannot be determined at any reading.

A

A. The accuracy is only at full scale, and that absolute number reading is carried through to the rest of the range. The upper 1/3 of the meter is the only truly calibrated part.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

3-75L5: Which of the following frequency standards is used as a time base standard by field technicians?

A. Quartz Crystal.
B. Rubidium Standard.
C. Cesium Beam Standard.
D. LC Tank Oscillator.

A

B. Rubidium Standard.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

3-75L6: Which of the following contains a multirange AF voltmeter calibrated in dB and a sharp, internal 1000 Hz bandstop filter, both used in conjunction with each other to perform quieting tests?

A. SINAD meter.
B. Reflectometer.
C. Dip meter.
D. Vector-impedance meter.

A

A. SINAD meter.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly