Items in Repair Locker Flashcards
Box Patch
- Used with shoring
- Used on jagged edges protruding inwards
Advantage: Can be welded to the ship
PECU (Portable Exothermic Cutting Unit)
10,000 F
- Battery (120 Volts)
- Torch
- Striker
- O2 Cylinder (2265 psi: 60 after reg)
PPE: Fire resistan gloves, fire resistant jacket, shade 5+ goggles, steel toe boots
S-type Eductor
100 gpm
20ft suction lift
1.5” inlet
2.5” outlet
Peri-jet
250 gpm
20ft suction lift
2.5” inlet (supply)
4” outlet (discharge)
ARGUS
Reads up to 392 F
Cannot see though:
- Glass
- Plastic
- Wide V
Battery Life: 4 hr
ATL takes ARGUS with a spare battery
Shoring Kit 9
Hammer
5lb Maul (2)
Hatchet
Cross-cut saw (2)
Carpenter Squares (2)
Carpenter Pencil
Folding ruler
Tape Measure
Wedges
Plugging Kit 11
Caulking Iron: packing Oakum into the seam between the planks.
Chisel: carving, cutting, shaping hard materials such as wood,
Oakum: used to seal gaps
Ball-pin Hammer: driving in wedges
5lb Maul: used ti make wedges tighter fit
Plugs: to plug holes or ruptures
Wedges: to wedge holes or ruptures
Cross-cut saw: cut wood plug or wedge
Hatchet: cut wood
Diver’s gloves: PPE. Better grip in water
Rags: clean up?
Access and Overhaul Kit 7
Shovel
Rake
Pickaxe
Halligan Tool: punch hole in door
Prying tool
Bolt-Cutters
5lb Maul
Pipe-Patching Kit 13
Ball-pin Hammer
Syntho-glass (150psi)
– NO potable Water
– Flammable liquids
– No Firemain
Marlin
Oakum
Rubber
Chisel
Caulking Iron
Hatchet
Hacksaw
Shears
Diver’s Glove
Wedges
Plugs
Reciprocating Saw
The thicker the blade, the thicker metal will cut.
Jubilee Patch
100 psi
Diameter 0.5”-8”
Can be used on:
– Flammable Liquids
– Steam
– Potable
: Best on ruptures with no protruding edges
Box Fan
3200 ft/min
115 volts
Used with:
- Door Jacks
- Smoke Curtains
Ram Fan
Runs on fireman
- 2000ft3/min at 180 psi
- 1750ft3/min at 125 psi
Used with elephant trunks
- No more than 3 trunks per fan
- each trunk is:
– 10 ft collapsed
– 15 ft extended
Must be grounded to bare metal
1.5” inlet and outlet
Discharge uses 25ft discharge hose Found in the hose fitting room
Requires SCBA if dealing with toxic gas
Investigators Kit 16
Message Blanks
Log sheets
Chalk
Dog wrench
Crescent wrench
Spanner wrench
Pipe wrench
QAWTS wrench
Fire Finder
Heat gloves
Pliers
T-handles
Grease Pencils
Sounding tape
Sounding pastes
Map
ESP (Submersible Pump)
Suction Lifts
– Under 50ft: 200 gpm
– 50-70ft: 180 gpm
– 70ft: 140 gpm
Use non collapsible hose
440 Volts
2.5” Inlet
2.5” Outlet
(Need double female coupling)
Need:
– Extension Cord
– Rubber Matt
– Rubber Insulated gloves:
– Found in RPE Kit
– Non-conductive boots (rubber, no steel toe, etc.)
Cannot pump flammable liquids
Not used when personnell in space
PKP Extinguisher
Weight?
Range?
Duration?
Repair 2: Inboard bulkhead forward of door to repair 2 overflow
Size: 20 lbs
Range: 40-50ft “566” and 15-21ft “415”
Duration: 29 s “566” and 28s for “415”
Fire:
1-Class B- Primary
—– Works by inhibiting the chemical chain reaction
2-Class C (Not recommended) Corrodes electrical equipment
3-Class K (Deep fat fryer)
CO2 Extinguisher
Weight
Range
Duration
Fire
Laundry, forward bulkhead
15lbs
Range: 4-6ft
Duration:40-45ft
Fire:
1-Class C: Primary (displaces O2)
2- Class A: Secondary (No refresh protection)
Ground cylinder prior to use
Beware of frostbite when handling
AFFF Extinguisher
Weight?
Range?
Duration?
Type of fire?
Main deck, starboard passageway, inboard, near entrance to galley line
2.5gal (27-30lb)
Range: 15ft
Duration: 55-65sec
Fire:
1-Class A (created vapor barrier between fuel and oxygen
BEST: Class B fires
Soft Patch
Low pressure piping
Effective on simple and compound ruptures
Use wooden wedges, sheet rubber and marlin
Overlap 2 inches past rupture
Has to have 2 full pases of marlin
What size hoses are in the repair locker?
1.5”
2.5”
4”