Integration with Building Systems and Construction 15% (Mech & Plumb) Flashcards

1
Q

Example of a VAV System

A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the minimum cubic feet per minute per person required to maintain proper Indoor Air Quality?

A

5 CFM per person

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are Grilles?

A

They REMOVE air from an indoor space adn return it to the HVAC system for reconditioning

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are Registers?

A

SUPPLY conditioned air into an indoor environment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What are Diffusers?

A

PUSH conditioned air into a space in a set pattern for optimal airflow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Where is a plenum located?

A

Between the ceiling and the structural floor above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

All supply air is connected to what?

A

Main duct work

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When fire partitions ar presented what must be provided?

A

Supply air ducts and openings for return air

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is a mixing box?

A

Adjust the quanity or temperature of air going into a space from the main supply lines

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What are thermostats connected to?

A

Mixing box

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

VAV boxes are typically placed where?

A

Above the ceiling within or near the space it serves

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Daylight sun pattern example

A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Where do ducts run?

A

Plenum or chase

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

When a duct passes through a fire rated wall or other assembly it must have what?

A

Fire stop

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Most HVAC systems use what for air return?

A

Duct or plenum

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What can be used in a fire area for air return a duct or plenum?

A

Plenum

17
Q

Can a plenum go trhough a stair shaft/well?

A

NO

18
Q

Access panels must be install in what kind of ceilings?

A

Gyp

19
Q

Do you need an access panel in a suspended ceiling?

A

NO since it allows for easy access

20
Q

What does AHU stand for?

A

Air Handling Units

21
Q

Where should thermostats be located?

A
  • Away from exterior walls
  • Away from heat sources and enclosed rooms
22
Q

How high are thermostates installed?

A

44” to 48”

23
Q

How far away from the inside of glass should air supply (vents) be located?

A

2”

24
Q

Ducts are noted with two numbers, 10x8, what is the first number and what is the second number represent?

A

Width and Height

10W x 8H

25
Q

What is a soil stack?

A

Carries human waste from toilets

Black water

26
Q

What is a waste stack?

A

Carries waste other than human waste

gray water

27
Q

What is a stack vent?

A

Connects to a soil or waste stack above the highest fixture and extended through the roof

28
Q

Plumbing Vent/Stack example

A
29
Q

All fixtures with floor drains must be on a what?

A

Plumbing trench

30
Q

All plumbing must be within how many feet from a trench?

A

10’

31
Q

In a multi user toilet room, how many toilets are required to be ADA?

A

1 or 5%

32
Q

In a multi user toilet room, how many sinks are required to be ADA?

A

1 or 5%

33
Q

Multi user toilet room example

A
34
Q

When calculating drinking fountains, is it split between men and women OR total for the buidling?

A

Total for the building

35
Q

If you have a multi story buillding, when calculating toilets do yo calculated the total per floor or by the entire building?

A

Per floor

36
Q

What is the distance limited to a toilet?

A

500 feet

37
Q

An AHU in a gyp board requires what?

A

Access panel