The most widely used circuits in industry
Open loop circuit
This returns fluid from the case drains back to the inlet of the main pump
Charge pump (part of a hydrostatic drive closed loop circuit)
In a hydrostatic drive what should the fluid viscosity stay within
16 to 39 St.
Fluid oxidization rate
Above 60 C the oxidization rate doubles every 5 C
Size of reservoir in hydrostatic drive
3/4 of charge pump capacity
A suction filter should not create a pressure drop of more than this
3 psi
If the broken drive shaft has crystallized grainy appearance at right angles to the shaft axis it is caused by
Coupling misalignment
if it appears twisted off then there is overpressure in the system
Electrical solenoids can be either
AC (120 V, large current inrush, can burn out) or DC (little current inrush, safer, won't burn out, but slower than AC)
The malfunctions you must fix on hydraulic systems are all symptoms of faults of these 3 things
Flow, pressure, and direction of flow
____ affects the speed of the actuator, _______ affects the force
Speed, Force
Two types of flow meters
Float - Tube indicator
Turbine - Electronic device attached
Two types of pressure gauges
Compound - Gives vacuum reading as well as pressure reading
Pressure Gauge
Which pressure gauge is recommended for hydraulic systems
Pressure gauge with venting isolation valve with palm button
The mechanism for protecting a gauge is called
Snubbers
Max temp in a closed loop system
80 C