HPSW PUMPS Flashcards
What is HPSW Operating Pressure?
+- 7 Bar
What is fitted to prevent system over pressurisation?
10% Leak off valve.
State 6 uses of HPSW?
- Fire Fighting.
- Pre Wetting.
- Fitted Bilge & Salvage Eductors.
- Emergency cooling to main propulsion Gas Turbines & Diesel Generators.
- Auxiliary Machinery cooling water system.
- Making Fresh Water.
Explain the flow of SW from sea to ringmain.
Sea, Suction Pump, Strainer, Pump, Riser, Ringmain.
Explain the HPSW Ringmain.
HPSW Ringmain is a complete loop/circuit of pipework, which is pressurized to 7 bar, located on 2 deck.
Where will HPSW Sprays be located?
- Magazines
- Paint Lockers
- Inflam Stores
- Funnels
Explain system configuration of DC State 1.
Individual HPSW pumps supply their own section of ringmain. The ringmain is isolated by shutting the state valves to minimize effects from damage.
Explain configuration in DC state 3?
All main isolating valves are open. With one pump supplying the while system. If there is a pressure drop, another pump can be started.
When may more pumps be introduced?
If there is an issue that causes pressure drop in the ringmain or an increase in load. Or, during special operations, such as flying stations.