How To Use Emergency Equipment Flashcards
Adult life jacket
Serviceability
How to use
Precautions
Put on head,pass tape around waist and tighten
Use tags to inflate
Present
Beacon 406s
Serviceability
How to use
Precautions
Water activated
Present
Transmit for 48 hours
In water: Antenna automatically deploys in water
On land:
Add one pouch of salt and one litre of liquid to the attached bag
Lower the base of the beacon into the bag to cover the vent holes with liquid
Note:if no water and salt available replace water supply at intervals of approx 12-24 hours a day to maintain full power output .
Use 4 table spoons of water with each half bag of water
Beacon 406se
Serviceability
How to use
Precautions
Present
Lithium battery
In water ensure ELT dial is in arm position prior to deployment in water
A flashing led will be visible after 10 seconds on top of transmitter cover
On land
Unfasten water soluble tape to release antenna
Turn elt dial to xmt (transmit) no liquid is required
A flashing led will be visible after 10 seconds on top of transmitter cover
Dme torch
Serviceability
How to use
Precautions
Present
Safety wired or plastic seal. Red light blinking
BFC
Serviceability
How to use
Precautions
Pass
Push up red catch
Squeeze the handle
Sweep the flames
Range:1.5 - 2 metres
Hold 60 degrees vertical
Minimum of 10 seconds
Serviceability: red plastic disk is intact at rear of handle
PBE should be worn, don’t get too close,do not allow any metal part of the extinguisher to make contact with live wires
Essex protective breathing equipment
pbe
Tamper prevention integrity seal is intact
Check humidity indicator is blue in colour
Precautions: move objects from around neck, ensure long hair is within neck seal
Oxygen flow is initiated by snapping the two cylinders apart which in turn activated the flashing green light on the service / end of service indicator
Should be an immediate hissing sound
Single outlet oxygen
- Ensure oronasal mask is plugged into outlet
2.shut off valve fully until number 4 is visible (above pressure gauge)
3.check inline flow indicator is green
Serviceability: pressure gauge needle is in between green band and full
100 psi should be left, passenger should be checked every 15 min
Precautions: no bumping, no ignition within 4 metres, avoid contact with oils or grease
Remove makeup from person before administering oxygen
Multi outlet oxygen
1.Select flow rate by plugging oronasal mask into appropriate outlet
2.shut off valve fully(anti clockwise) then turn back a half turn
3.check inline flow indicator is green
Serviceability: pressure gauge needle is in the red band
100 psi should be left, passenger should be checked every 15 min
Precautions: no bumping, no ignition within 4 metres, avoid contact with oils or grease
Remove makeup from person before administering oxygen
Flight deck Eros oxygen
Pressure gauge needle is in red band
Flight deck oxygen bottle with an eros outlet may be identified by a yellow band around the top(brass fitting)
1.disconnect flight deck mask from aircraft oxygen system
(To disconnect flight deck mask from the aircraft oxygen system, twist and pull the bayonet fitting located inside the Eros housing)
2.plug flight deck mask fitting into the cylinder eros outlet (the bayonet fitting on the mask attaches to the brass outlet on the flight deck cylinder)
- Open the shut of valve fully (anti clockwise)then back half a turn
Max duration is 15 min
Efak
Present and sealed