1) Identify and resolve fault conditions of modules/subsystems including power supplies. 2) Prioritize repairs of medical devices based on level of risk and/or urgency. 3) Differentiate between a device error and a use error (User Training, Applications) to determine appropriate action. ~Monitoring Equipment~ 1) Differentiate between an issue with a localized monitoring device on a network and a systemwide problem. 18 2) Identify the fault conditions and apply appropriat

1
Q

Medical device used during cataract surgery to break up and suction out cloudy lens.

A

phaco emulsifier

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Used by orthopedic surgeons for exercising injured joints, sometimes ordered after knee surgery.

A

CPM machine

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What does a balloon pump, and defibrillator use in sync mode to trigger?

A

ECG R-wave

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

AAMI ECG Lead III placement and colors.

A

LA (black), LL (red)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

AAMI ECG Lead II placement and colors.

A

RA (white), LL (red)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Balloon pump is used in emergency situations such as ________.

A

Heart attack or congestive heart failure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Pertaining to artificial ventilation, peak flow (LPM) sets ________.

A

maximum speed at which the gas flows into the patients lungs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Hospital O2 wall pressure at the outlet is?

A

50-55 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Operating principle of a mass spectrometer relies on effect of an ________ on a stream of ionized gas molecules.

A

magnetic field

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

A Sequential Compression Device (SCD) is used in bed-ridden patients to prevent what?

A

deep vein thrombosis

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

A balloon pump can be used during a waiting period in anticipation of a ________.

A

heart transplant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the name of the device used to help blood flow from the left ventricle to the coronary arteries while increasing cardiac output with less left ventricular workload?

A

Intra-aortic balloon pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Surgical instruments should be ________ for laser cases to limit injury by reflection of coherent light

A

Ebonized

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Most commonly used gas for an insufflator.

A

CO2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Typical defibrillator test load.

A

50 Ohms non-inductive

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Calibration voltage used in ECG

A

1 mV

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

This component on an IV pump will prevent free flow.

A

mechanical interlock

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

An ESU generator’s ability to coagulate without cutting

A

High crest factor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

ESU cut function is characterized by high ________ with a low crest factor.

A

duty cycle (100% on)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

What cardiac rhythm would use the defibrillation (non-sync) mode on a defibrillator?

A

Ventricular fibrillation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Device used in clinical laboratories for measuring the concentration of particles in a solution.

A

Osmometer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

On a pulse oximeter, the ratio of absorption = ______

A

O2 saturation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Balloon pump should inflate when the heart is ________.

A

at rest and diastole

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

The percent rejection reading of a reverse osmosis system is fluctuating much more than normal. What could cause this?

A

Conductivity meters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
A balloon pump can be used during patient stabilization awaiting ________.
cardiac procedure
26
Laser light is?
Coherent
27
A spirometer is used to ________.
Assess how much air is inhaled and exhaled.
28
What cardiac rhythm is a defibrillator set to cardioversion sync mode for?
Atrial fibrillation
29
Medical device used for examining inside of the ears.
otoscope
30
In a home health CPM machine, what does "CPM" stand for?
continuous passive motion
31
Defibrillation shockable rhythms include: ________ and ________.
Ventricular Tachycardia and Ventricular Fibrillation
32
________ effect is used to generate and detect ultrasound waves with piezoelectric ceramic materials.
Piezoelectric
33
Bowie-Dick test and Dart test measures for what?
Proper vacuum phase operation in a autoclave sterilizer.
34
IV pump occlusion sensors are usually sensed by ________ or ________.
pressure transducer, stall (current) sensor
35
ESU blend function is characterized by a duty cycle between ________ and ________.
cut, coag
36
Sector (vector) and Linear (rectangular) are examples of two types of ________.
ultrasound probes
37
Laboratory equipment used to make very thin slices of tissue
microtome
38
For invasive blood pressures, the transducer measuring the blood pressure must be ________ with the tip that is inserted into the body.
level
39
Absorbs CO2 in anesthesia machine.
Soda lime
40
Autoclave sterilization cycle.
Air removal, heat/pressurize, sterilization, cool/depressurize, dry.
41
ESU coag function is characterized by low ________.
duty cycle (6% on, 94% off)
42
What type of gas is typically used in an intra-aortic balloon pump?
Helium
43
A nebulizer ________ liquid.
atomizes
44
ECG waveforms are permanently stored in ________.
EEPROM
45
Electrosurgical units operate between the frequencies of ________ and ________.
100 kHz, 5 MHz
46
Gamma camera and scintillation counter are used primarily to study body organ ________.
function
47
Balloon pumps patients in are typically in ________ and are ________
CICU’s, critically ill
48
Balloon pump triggers on ________ wave.
R
49
Used to measure lung residual volume (RV), total lung capacity (TLC), airway resistance, and intrathoracic gas volume (ITGV)
Plethesmograph
50
Pertaining to artificial ventilation, frequency/breath rate (BPM) sets ________.
number of breaths delivered per minute
51
During pulmonary studies, integration of the flow signal can be used to measure ________.
lung volume
52
AAMI ECG Lead I placement and colors.
RA (white), LA (black)
53
What is used to eliminate abnormal electrophysiological impulses in the heart?
Cardiac ablation
54
What ECG lead is used for respiration?
Lead II, white and red, RA to LL
55
Tourniquet machines used to stop blood flow to surgical sites use what gas?
N2 (Nitrogen) or air
56
IV pump air-in-line sensors are usually ________ or ________
optical, ultrasonic
57
Key component when a sterilization process uses plasma.
H2O2 (Hydrogen Peroxide)
58
Optimal balloon pump timing set by ________ pressure tracing.
arterial
59
On a pulse oximeter, the LED emits two lights at what different wavelengths?
Red and Infrared
60
PEEP stands for what?
Positive end-expiratory pressure
61
Most common temperature for infant incubator.
98.6 degrees F, 37 degrees C
62
Empirical gas law that states that when the temperature of a given mass of confined gas is constant, the product of its pressure and volume is also constant. P1V1 = P2V2 or pressure is inversely proportional to volume.
Boyle's Law
63
Defibrillator is used to correct this situation with the heart.
Ventricular fibrillation
64