Dead End
The lowest possible pressure obtainable using given vacuum pump, with the suction valve closed
Solenoid Valve (SV-1) Vacuum Pump Safety Feature
Closes when the pump motor turns off or during a power loss to prevent back leakage through the pump
Vacuum Pump Power Requirements
3/4 HP Motor
440 VAC
3 Phase
60 Hz
Pump Assembly Construction Features
Aired cooled, rotary piston, high-vacuum pump consisting of two rotary piston pumping stages
Vacuum Pump Discharge Valve
Spring loaded valve consisting: 2 Plates 2 Springs 2 Bolts Prevents backflow of gas after discharge
Vacuum Pump Center Wall Seal
Made of Viton
Prevents equalization of pressure between high Vacuum and backing stages
Vacuum Pump Suction Valve V-14
Diaphragm type
Isolated annulus from solenoid valve and vacuum pump
Vacuum Pump Solenoid Valve SV-1
Diaphragm type
Protects the annulus from backflow and maintains vacuum
Vacuum Pump Valve V-22
Below seal type
Used to depressurize annulus space
Vacuum Pump Functional Operation
The oil forms a vacuum-tight seal between the piston and the cylinder wall, as well as between all of the working components
Vacuum Pump Gas Ballast Valve
Angle type valve