O2N2 Distribution Panel Components
Piping
O2 and N2 system piping and fitting shall comply with MIL-STD-777
O2N2 Distribution Panel Components
Reducing Manifolds/Valves
Operational function, provides a means of reducing gas system to a usable working pressure
Reducing gas system to usable working pressure for O2
O2 -3000 PSIG
O2 -3000/50 PSIG
Reducing gas system to usable working pressure for N2
N2 -5000/3500 PSIG
N2 -5000/2000 PSIG
N2 -2000/50 PSIG
Storage Flask for O2
Green
Storage Flask N2
Grey
Charging Stations
Metal cabinet with lockable door
Mounted to bulkhead
Tare Weight
The combined weight of a cylinder and valve assembly without cap
O2 Operating Pressure for Flask and Cylinders
3000 PSIG Flask
1800-2400 PSIG Cylinders
N2 Operating Pressure for Cylinders
1800-2265 PSIG
Anchor Windlass Cylinder
500 PSIG
Cylinder Specification (3 sections)
DOT -Department of Transportation
3AA -Specification of type and material of cylinder construction
2265 -Service Pressure in psi
Manufacturing Data
4-70 -Date of manufacture and original test date
XX -Inspector’s official mark
+- -Cylinder qualifies for 110% filling
YY
Manufacturer’s identifying symbol
Retest Markings
4-75 -Data of first 5 year hydrostatic retest
ABC -Retester identifying symbol
+- -Cylinder requalifies for 110% filling
*- -Cylinder qualifies for 10-year retest interval