List the four electrical circuits on a forced warm-air furnace.
Combustion safety circuit.
Control circuit[][][][][][][][][][][]
Fan circuit[][][][][][][][][][][][][]]
Transformer circuit[][][][][][]]
True or False?
All control systems have these four basic circuits:
Combustion Safety Circuit.
Control Circuit[][][][][][][][][][][]
Fan Circuit[][][][][][][][][][][][][][]]
Transformer Circuit[][][][][][][][]
False.
Identify the basic components of a Combustion Safety Circuit.
Safety shut off valve (switch).
Thermocouple[][][][][][][][][][][][][]
How many volts are generated by a single thermocouple?
25 - 30 mV.
Describe a thermopile and list the two types.
When one or more thermocouple is wired in series, the unit is called a thermopile. Coaxial and Modern.
Describe the difference between 100% safe switches and non-100% safe switches.
100% Safe: Shut off gas to burner and pilot.
Non-100% Safe: Shut off gas to burner[][][][]]
True or False?
Safety switches are commonly used on equipment having an input of over 400 cu ft/h.
True.
Explain why switches are always put in the hot leg of a circuit.
If in the hot leg, there will be no electricity connected to the appliance and no shock hazard when working on appliance when switch is off.
True or False?
A single pole, single throw switch can energize one of two different circuits or loads.
False.
True or False?
A double pole, single throw switch can open and close two independent circuits at the same time.
True.
True or False?
A normally open flow switch is open when current flows.
False.
True or False?
The high-limit switch is a normally closed switch that opens if overheating occurs.
True.
True or False?
An operating aquastat senses water temperature and de-energizes the main gas valve when the tempurature reaches the set point.
True.
True or False?
A high-limit aquastat is a back up to the operating aquastat but is adjusted to a higher set point.
True.
What will happen if the voltage designation of the gas valve’s magnetic coil does not match the power supply?
The valve coil may burn out or not operate the valve.