Fourth Year - Block C Drainage, Waste & Venting and Private Sewage Disposal Flashcards
When do you need a spectic tank and what is it’s purpose?
When the property is not hooked up to the city’s septic system.
Break down solids[][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][][]
What are the two major components of a septic system?
Disposal field (Type 1).
Septic tank (Type 1)[][]]
What are the three layers that make up the effluent in a septic tank?
Scum - Top layer.
Clean liquid - Middle layer.
Sludge - Bottom layer[][][][]]
Where are the anaerobic bacteria present?
In the tank.
How long should a septic tank be able to hold sewage for?
24 hours.
What things would you consider when determining the expected daily sewage flow for a septic tank?
Cloths washer.
Garbage grinder.
Number of bedrooms.
Number of people[][][]]
Type of occupancy[][][]
What would determine the location of a septic tank?
Buildings.
Distance from property lines.
Water sources[][][][][][][][][][][][][]]
What types of things do you take into consideration when sizing a septic field?
Cloths washer.
Frost line[][][][]]
Garbage grinder.
Number of bedrooms.
Number of people[][][][]
Type of occupancy[][][][]
Type of soil[][][][][][][][][][]]
Water table[][][][][][][][][][]
What would you do if a septic tank is installed but you find that all the locations for a specific septic field end up being either too close to a property line or too close to a water source?
Install a pumpout (Holding tank - Drained once in a while).
No disposal field is used in this situation[][]][][][][][][][][][][][][][][]
What is the purpose of a distribution box?
Distributes the effluent to the field evenly.
What is the reason for the siphon tank being sized so that it discharges a large amount of effluent at one time?
Ensures that the entire disposal field is used.
What is the purpose of item “A” in the picture below?
To allow the cleanest liquid to enter.
What type of soil would you use as fill for a disposal field?
Porous soil in order to allow air to reach the gravel bed.
How do you test the suitability of the soil or the proposed disposal field?
Percolation test.
Dig two 12 x 12 holes 22 -32 inches in depth at either end of the field.
Test must be done for 1 hour to see how quickly ground absorbs water in the holes.
Rather than using a distribution box to distribute the clear effluent from a septic tank, you may instead install a header. How should the header be graded?
Level w/ the branches then sloped away from the header at a grade of 2” / 100 feet.