First Line Maintenance Device Flashcards
1
Q
First Line Maintenance Device Overview
A
The First Line Maintenance Device (FLMD) is a laptop computer used to access diagnostic software resident on CPUs within the Electronics Unit. The FLMD can perform intrusive or non-intrusive maintenance.
2
Q
Intrusive Maintenance Overview
A
Intrusive diagnostics are performed with the VOBC in the maintenance state as these commands interfere with the operation of the VOBC.
3
Q
Non-Intrusive Maintenance Overview
A
Non-intrusive diagnostics are performed in real time with the VOBC in the passive or active state and do not interfere with the VOBC operation.
4
Q
Intrusive Maintenance Connection
A
- Remove power from the VOBC.
- Connect and power on the FLMD.
- Open TeraTerm.
- Setup TeraTerm with the correct settings.
- Power on the VOBC.
- Press ‘enter’ within six seconds so that the VOBC enters maintenance mode.
- Enter the diagnostic command for the information required.
5
Q
Non-Intrusive Maintenance Connection
A
- Connect and power the on FLMD.
- Open TeraTerm
- Setup TeraTerm with the correct settings.
- The terminal will display a continuous steam of real time data.
- When the vehicle is stationary press enter to stop the real time dump and enter NI maintenance mode.