Fire Protection Flashcards

1
Q

What does the amber SMOKE light in the GEN 1 LINE pb indicate?

A

Smoke detected in the avionics ventilation ducting

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Will there be any indications when the SMOKE light illuminates on the GEN 1 LINE pb?

A

ECAM warning and amber fault lights in the EXTRACT and BLOWER pbs on the ventilation panel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Where are the engine fire loops installed?

A

Pylon Nacelle
Engine Core
Fan Section

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What happens if both fire loops fail?

A

If the failure of both loops occur within 5 seconds of each other, a FIRE warning will be issued

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What does an amber DISCH light mean?

A

The fire extinguisher bottle has lost its pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How many fire extinguishers are provided for each engine?

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What occurs when the ENG FIRE PB is pressed?

A

-Silences the aural fire warning and arms the fire extinguisher squibs

  • Closes the HYD fire shutoff valve

-Closes the low pressure fuel valve and the IDG return fuel valve

-Deactivates the IDG (FADEC power supply also deactivated)

-Closes the pack flow control valve and engine bleed valves

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What occurs when you press the TEST pb on the ENGINE FIRE panel?

A

7 lights
CRC sounds
MASTER WARN lights flash
ENG FIRE PB illuminates red
SQUIB and DISCH lights illuminate
ECAM Fire warning
FIRE light on the ENG Panel illuminates

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How many fire extinguishers are provided for the APU?

A

1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Does the APU Fire Extinguisher automatically discharge if a fire is detected in flight?

A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What happens when you press the APU FIRE PB?

A

-Silences the aural fire warning and arms the APU Fire squib
-Shuts down the APU
-Closes the low pressure fuel valve and APU fuel pump
-Deactivates the APU GEN
-Closes the APU bleed and X Bleed valves

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What occurs when you press the APU FIRE TEST?

A

-CRC sounds
-5 Lights
-MASTER WARN lights flash
-APU FIRE pb illuminates red
-SQUIB and DISCH lights illuminate
-ECAM FIRE WARNING

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Does the APU fire extinguisher automatically discharge if a fire is detected on the ground?

A

Yes. APU automatically shuts down and discharges the fire extinguisher

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

How many fire extinguishers are provided for the cargo compartments?

A

1 bottle, which can be discharged into either compartment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What does the red SMOKE light in the FWD or AFT pb indicate?

A

Both channels detect smoke OR
One channel faulty and other detects smoke

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

How many smoke detectors are there?

A

2 FWD
4 AFT

17
Q

With a CARGO SMOKE warning, what will happen to the isolation valve and extract fan?

A

Isolation valve closes
Extract fan stops