Fire Flashcards
How many loops to detect an APU fire for it to automatically shutdown in attended or unattended modes?
2 in the air, 1 on the ground
What happens if you get an AFT CARGO FIRE warning in flight
The 2 high rate bottles discharge automatically and the 3 low rates discharge after 15 mins slowly
On the ground, how many bottles will go into the hold?
Both high rate and one low rate
Why if the fire extinguisher system is automatic for the cargo holds, do you need to push the cargo fire button?
To reduce airflow to the cargo hold:
It does things like turns the lower recirc fans off, decreases flow from the packs, IFE cooling off etc
If you get a cargo fire warning on the ground, is extinguishing automatic
No
For the cargo fire suppression system, when does the DISCHARGE light come on?
As soon as the 2 high rate bottles are discharged
Are the wheel well, engine and apu fire loops dual channel or singlle?
Dual