Fire Flashcards
What is the oven content fire drill?
If fire is evident when an oven door is opened:
- Immediately close the door
- Turn the power off. If the power cannot be turned off, pull the circuit breaker for the
affected oven.
- Allow the fire to burn out
- Inform the ISM and the Captain
The situation should be monitored and if the situation worsens:
- Open the oven door just enough to insert the nozzle of a BCF/HAFEX fire extinguisher
(consideration should be given to donning a PBE and protective gloves)
- Discharge a small amount of BCF, close the oven door and monitor the situation
- Repeat the procedure if necessary
What is the electrical fire drill?
- Turn the power off. If the power cannot be turned off, pull the circuit breaker for the affected piece of equipment.
- Use the BCF/HAFEX fire extinguisher to put out the fire
- Inform the ISM and the Captain
How do you cancel the aural alarm of the lavatory smoke detector?
Airbus: Press any SMOKE LAV/SMOKE RESET button on FAP or AAP 777: Press the flashing amber call light outside the respective lavatory
If the lavatory smoke detector activates, what should you do?
- Identify the lavatory and cancel the chime (if possible)
- Check if the lavatory is occupied. If so, knock on the door and ask the passenger to
come out. Check the lavatory thoroughly - If nobody is in the lavatory, remain outside the lavatory and alert other crew. Other
crew will prepare the fire fighting equipment - Feel the door using the back of the hand. Check if ‘heat’ is present and look at the
edges of the door for any sign of smoke - If there is no heat or smoke, push open the door slowly and check for fire. If fire is
not evident, enter the lavatory and check it thoroughly - If when feeling the door heat is present or smoke is visible, carry out the lavatory
fire fighting procedures
What are the lavatory fire fighting procedures?
- Don PBE and protective gloves, have BCF/HAFEX extinguisher in hand
- Stay low
- Use the toilet door/partition as protection as the door is opened
- Locate the source of the fire
- Discharge the extinguisher at the base of the fire
If unable to enter the lavatory (due to severity of the fire and smoke) and unable to locate the source: - Open the door slightly and raise the extinguisher as high as possible
- Place the nozzle of the extinguisher in the gap
- Discharge the full bottle of BCF/HAFEX and close the door
- Reopen the door after half a minute and re-evaluate the situation
- If necessary, discharge another bottle
What are the immediate actions upon discovering fire or smoke caused by a PED or Lithium battery?
- [Remove external electrical power and/or switch off the power from device, if applicable
- Carry out fire fighting procedures using fire extinguisher until visible flames have been extinguished
- Use non-flammable liquid (such as water or liquid) to provide sufficient cooling]
- Repeat the above steps as required and monitor for any re-ignition
- Inform ISM and Captain
A350: What are the immediate actions upon discovering fire/smoke from a passenger seat?
- Set the PAX SYS and PED POWER to “OFF”
- Locate the source of fire/smoke and carry out appropriate fire fighting procedures
- Inform ISM and Captain
- PAX SYS and PED POWER shall remain OFF for the remainder of the flight
- Monitor the area