FADEC Flashcards
1
Q
How many light are associated with FADEC failure?
A
3 light conditions
- GOV Red - Major failure (stepper motor frozen
- GOV Amber - Minor failure (response time may be affected but the essential control functions are ensured
- GOV Flashing Amber - when twist grip leaves the “Flight” position. Minor fault (redundancy failure) no effect on engine performance
2
Q
Where is the ECU located?
A
Mounted in the cargo compartment
3
Q
How is fuel flow governed?
A
2 fuel metering valves/units in the HMU
Main Fuel Metering Unit
Back-up Fuel Metering Valve (EBCAU)
4
Q
Describe the Main Fuel Metering Unit
A
- Needle assembly which regulates fuel flow
- Dual actuators (2 step motors - Channel A and B) drive the needle assembly based on ECU signals
- Position transmitter send needle info to ECU
5
Q
Describe the Back-up Fuel Metering Unit
A
EBCAU. Purpose: back-up governing and fuel metering valve
- composed of a back-up electrical actuator
- actuator controls a valve
- valve allows flow of additional fuel
6
Q
What happens when a Major FADEC failure occurs
A
- FADEC freezes position of Main Fuel Metering Valve
- FADEC sends “major failure” signal to EBCAU
- EBCAU activated - red + amber GOV lights ON
- EBCAU maintains constant N2/Nr