Evolution 21 & 21A aerial as water tower Flashcards

1
Q

Upon the command to place the aerial as a water tower into operation, what is the proper position of the rig from the building?

A

25’-35’ w/ turntable centered for max. coverage of stream.

3.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Your the LCC on the 6x driving a new LT. around. you catch a job & are ordered to set up a water tower. once your in operation the officer tells you to extend the fly ladder to 70’. Do you AGREE/DISAGREE?

A

DISAGREE. The max. extension of the fly ladder is 80’, however once water is flowing you shall not extend or retract until water is shut down.
notes H, I

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

After the last job you said fuck this shit I’m going to an engine. You became an ECC and are working a 9x w/ a new boss. Your ordered to supply a aerial water tower. What is the max. pressure you should supply them?

A

90 PSI

3.6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The ladder angle must not exceed how many degrees?

A

70

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Where is the ladder pipe clamped?

A

center of top 2 rungs of top sliding section of aerial.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly