EQUIPTMENT Flashcards
Lavatory smoke detector pre-flight check
Correct location,
correct serviceability
Lavatory fire extinguisher pre-flight check
Make sure flap door is closed
Portable oxygen bottle, pre-flight check
Correct location
secured in brackets
No oil or grease
Dust covers are in place
Present mask
Minimum 1500 PSI
Portable oxygen bottle, flow, rate and purpose
Hi Flo, 4 L, 50 minutes, first aid use.
Low flow 2 L 100 minutes depressurisation use
Portable oxygen operations
Away from the passenger we are going to connect the mask. Check that it works and take it to the passenger. Pop the mask on the passenger and secure it.
Portable oxygen after use
Wrap it in a blanket, place it in an overhead locker, place mask in a sick bag
Portable oxygen precaution
Do not operate near flame
. Remove make up and oil
avoid contact with oil or grease
store in cool place.
Do not bump or drop
do not force mask if passenger, refuses,
and do not go below 50 PSI
Pre-flight check megaphone
Correct location secured in its brackets
and serviceable with an audible chirp
and green light
Megaphone purpose
evacuation
crowd control,
PA system fails
Torch, pre-flight check, 190
correct Location
secured in its brackets
serviceable with flashing light, and
Tamper, seals are intact
torch pre-flight check 170
correct Location
secured in its brackets s
serviceable LED light visible
What is the torch purpose?
Post evacuation s
smoky conditions
to direct passengers
emergency use only
Restraint kit pre-flight check
Correct location, correct number three Flexi, cuff
one pair of cutters
restraint kit precautions
Avoid over tightening
must to get permission from Captain
restrained until handed over to police.
Second pair of cuffs placed first, after removing the first scuffs.
prepare, away from Passenger
Never tape or use extension seatbelt for extra security
adult lifejacket pre-flight check
Correct location, correct number
170 6 infant lifejackets, 5 adult lifejackets
190 12 infant lifejackets, six adult lifejackets
Lifejacket precaution
Must not inflate the ADULT LJ, t in the aircraft
lights last for 10 hours.
Infant lifejacket must be inflated inside the aircraft.
Differences between adult and infant lifejacket
Press stud
crutch strap
pull, tabs,
lanyard
no whistle
Universal protective kit contents
- Respiratory masks
2 safety spectacle
80x Health locator forms on the 170,
100x health locator forms on the 190
5p
12 semi com Wipes
It’s used for sickness
Biohazard bodily fluid kit contents
Waste absorbent,
scoop and scraper,
face mask and shield gloves,
apron,
waste disposal, bag,
anti septic wipes,
used for bodily fluid cleanup
daily First aid kit pre-flight check
correct Location,
sufficient Band-Aids
emergency First aid kit contents
First aid book,
saeline, tweezers,
scissors, triangular bandages
eye pads
emergency First aid kit pre-flight check
Correct location,
Tampa, seal intact,
expiry date
secured in bracket
Fire glove, pre-flight check
Correct location, serviceable, no holes and tears
Halen bcf pre-flight check
Correct location
secured in bracket
pin in place
gorge in the green band
Tamper seals
Chubb pre-flight check bcf
Correct location
secured in bracket,
Red latch down
red disk visible
BCF symptoms
Watery eyes, runny nose,
dry throat,
difficulty breathing,
skin and eye damage
BCF precautions
Not suitable on metal or oil fires
Do not spray directly on passenger
Do you not spray on wires
Beware of liquids
Chubb duration
15 seconds, 1. 5 kg
range 1.5 m to 2 m.
Max range 3 m
Halen duration
10 seconds
1 kg
range 4 m
Chubb PASS
Push-up red latch
aim at base of fire,
squeeze handle,
sweep flames
Halen PASS
Pull up lock pin
aim at base of fire
squeeze handle
sweep flames
After use of BCF
Put back in place accessories
put back in storage place
Draeger Oxy crew duration
20min
PBE purpose
Used with and fire extinguisher in a confined space
Also, clean up DG spills from fumes
puritan bennett duration
15m
Precautions of PBE
Activate before fasting
insure next seal is free of obstruction
shall not open neck seal after donning
remove away from flames
insure waist strap is fastened
Remove jewelry and clothing
Battery back on back gets hot
Draeger Oxy crew pre-flight check
Correct location
secure in brackets yellow seal, cut, not broken
Tampa seal intact,
expiry date
puritan bennet preflight check
Correct location
secured in bracket
pouch not expanded
tamper seal intact
What happens if puritan Bennett does not want to start?
Pull two times and if it does not start to operate exhale
Aircraft systems lavatory, call
Orange high chime
Systems smoke detection
Orange flashing, intermittent, high chime
Passenger call aircraft systems
Solid blue high chime
emergency call aircraft systems
Red three times Highlow chime
Flight deck to Cabin Crew call
green flashing green highlow chime
cargo Compartments
fire Extinguisher and detection
cabin oxygen oxygen duration + INFORMATION
12 minutes
Manual deploy tool can be used always in the armed mode cabin pressure at 14,000 feet automatically drops Pilot to have a switch Pilot must where oxygen mask of 10,000 feet cabin pressure. At 13,000 feet Cabin Crew AND passengers must where oxygen mask
Above each crew station cabin, oxygen
2 LHS 2 RHS 4
170 mask OXYGEN
RHS 3
LHS 3
CREW STATION 8 INCLUDING TOILET
190 MASK OXYGEN
RHS 3
LHS 2
INFANTS MUST SIT IN RHS
CREW STATION 8 INCLUDING TOILET
Activate cabin oxygen
manuel deploy tool
always in armed mode
13000ft cabin and pax must wear oxygen
cabin pressure 14000ft automatically drops
pilots have a switch
pilots must wear drop down oxygen at 10000ft
Flight deck systems
master going off means…
indication for smoke and location
flight deck systems, armed emergency
can turn on
flight deck systems disarmed emergency
cannot turn lights on from cabin
flight deck door
only use handle to open/close door
only use cabin control if both pilots incap
land evacuation 170/190
use all exits sliding off from the bakc
water evacuation 170
only use front exits
water evacuation 190
all exits and jump from the back