Environmental Systems & Anti-Ice Flashcards
Bleed air (at TRT) normally doesn’t exceed…
600 degrees F, 125 psi
AIR COND FAIL annunciator & ACU will shut down if exit air temp exceeds ___ F, or compressor inlet pressure exceeds __ psi
400, 53
CABIN AIR OV HT illuminates at
390 +/- 15 degrees F in cabin vents
The _ switches in aft compartment will trigger BL AIR DUCT FAIL at ___ F (or an anti-ice problem)
4; 350
(Pressurization) How many outflow valves?
2
Bleed air pressure to cabin door seal
15 psi
Cabin rate of climb is adjustable between __ ft and ____ ft
50 to 2000
CABIN PRESSURE HI illuminates
11 +/- 1 psid
Outflow valves should keep cabin differential pressure from exceeding…
9.1 psid
CABIN PRESSURE LO illuminates
9,500 +/- 500 ft cabin altitude
With cabin outflow valve at full decrease, cabin altitude may climb as high as
12,500 +/- 500 ft
Prolonged use of EMER pressurization can…
melt trim panels, lead to smoke and fumes
When throttles are advanced to T/O, cabin pressurizes approx
80 to 120 feet
How many evaporator blower units are in the cabin?
3 (fwd, aft, and avionics - not counting stby avionics)
AV BLO FAIL
lack of pressure from the avionics blower
The VCCS (vapor cycle cooling system) is located…
in the aircraft nose
VCCS is auto depowered if (3 conditions):
1) engine start. 2) windshield heat. 3) horiz. stab. anti-ice/de-ice
The only possible power source for electrical heat is…
ground power unit
How many electrical heater elements are there?
3
Bleed air switch must be in the ___ position to use “ground air”
OFF
ICING illuminates when the detector senses ___ inches of ice
0.020